Uni-Patch Softy Model 699 Electrodes — 1.75" Square, Side Pin, 40/Pack
Out of stock
🛡 Authorized Dealer - Authentic Products & Manufacturer Warranty
💲Price Match Guarantee
🚚 FREE & FAST Shipping
◆ Easy, Secure Checkout
💬Questions? Contact Our Product Specialists
Uni-Patch™ Softy Model 699 Electrodes — 1.75-Inch Square, Side Pin, 40/Pack
Uni-Patch™ Softy Model 699 Electrodes are compact, self-adhering electrotherapy pads that work with TENS, NMES, EMS, and FES stimulation systems.
Each electrode measures 1.75 × 1.75 inches and combines a soft, flexible foam backing with reinforced conductive solid gel. The smaller square footprint is useful where a standard 2 × 2-inch electrode may be larger than desired or where two electrode pads must fit within a more confined placement area.
This Balego package contains 40 electrodes and uses the EC89455 side-pin connection. Match the connector to the device’s lead wires before ordering.
The Model 699 is a self-adhering, reusable, soft-foam stimulating electrode for TENS, NMES, and FES.
Product Highlights
- Uni-Patch™ Softy Model 699
- Manufacturer item number EC89455
- Balego SKU 699/40
- Compact 1.75 × 1.75-inch square shape
- Self-adhering conductive gel
- Reinforced solid-gel construction
- Soft-foam backing
- Reusable for the same patient according to the product listing
- Side-pin lead-wire connection
- Suitable for compatible TENS, NMES, EMS, and FES systems
- Forty electrodes per package
- Nonsterile
- Prescription-use product
Quick Product Specifications
| Specification | Product detail |
|---|---|
| Product | Uni-Patch™ Softy Model 699 |
| Manufacturer item number | EC89455 |
| Balego SKU | 699/40 |
| Electrode type | Self-adhering stimulating electrode |
| Size | 1.75 × 1.75 inches |
| Metric size | Approximately 4.45 × 4.45 cm |
| Shape | Square |
| Backing | Soft foam |
| Gel | Reinforced conductive solid gel |
| Connection | Side-pin connection |
| Modalities | Compatible TENS, NMES, EMS, and FES systems |
| Package quantity | 40 electrodes |
| Reusable | Yes, for the same user and according to labeling |
| Sterility | Nonsterile |
| Prescription status | Prescription use |
| Brand | Uni-Patch™ |
| FDA labeler | Cardinal Health, Inc. |
| UDI | 10884521167841 |
What Are Softy Model 699 Electrodes?
The Softy 699 is a compact hydrogel-style stimulating electrode intended to carry electrical current from a compatible stimulator through the skin.
Its basic construction includes:
| Electrode layer or feature | Function |
|---|---|
| Soft-foam backing | Helps the pad conform to the treatment area |
| Reinforced conductive solid gel | Provides adhesion and electrode-to-skin electrical contact |
| Square conductive surface | Creates a defined stimulation area |
| Side-pin connector | Connects directly to a compatible lead-wire pin |
| Storage liner | Protects the adhesive surface between uses when included with the package |
The product description highlights that the reinforced gel makes the whole electrode surface conductive and self-adhering, while the soft foam allows for comfortable, conformable placement.
What Does “Side-Pin Connection” Mean?
The EC89455 is specifically the side-pin version of Model 699.
A compatible lead-wire pin inserts into the connection point at the side of the electrode. This differs from electrodes that use the following:
- A molded pigtail socket
- A metal snap
- A flat tab
- A proprietary plug
- A garment or wrap connection
| Connector style | How it attaches |
|---|---|
| Model 699 EC89455 side pin | The lead-wire pin connects at the side of the pad |
| Pigtail/socket electrode | The device pin connects to a short wire extending from the pad |
| Snap electrode | The lead wire snaps onto a metal stud |
| Tab electrode | A clip or adapter attaches to a flat conductive tab |
| Proprietary electrode | Uses a manufacturer-specific connector |
Do not purchase electrodes based on shape and size alone. Connector compatibility is equally important.
For an explanation of common electrode connectors, visit our TENS electrode buying guide.
Why Choose a 1.75-Inch Square Electrode?
A 1.75-inch square electrode has a slightly smaller footprint than the common 2 × 2-inch pad.
It may be useful when:
- The available placement area is limited
- Two pads must fit close to one another
- A smaller muscle or anatomical region is being targeted
- A clinician wants more focused placement
- A standard 2-inch square pad extends beyond the intended area
- A clinic is replacing an existing Model 699 setup
Electrode size affects current density. At the same stimulator output, a smaller pad can feel more concentrated than a larger electrode. Intensity should therefore be returned to zero whenever electrodes are changed, followed by gradual readjustment.
Compatible Electrotherapy Modalities
| Modality | General purpose | How Model 699 may fit |
|---|---|---|
| TENS | Sensory-level pain modulation | Compact placement around or near the treatment area |
| NMES / EMS | Motor-nerve and muscle stimulation | Placement over appropriately selected muscle or motor-point regions |
| FES | Stimulation coordinated with a functional movement | Compact electrode option when compatible with the prescribed system |
| Other stimulation | Device-dependent | Use only when permitted by the stimulator and electrode instructions |
TENS, NMES, and FES are not interchangeable treatment goals even when they use similar electrode pads. Read TENS vs. NMES for a detailed comparison.
Forty-Electrode Package
The Model 699 package contains 40 individual electrodes.
This package size may be useful for:
- Physical therapy clinics
- Occupational therapy departments
- Sports medicine practices
- Chiropractic rehabilitation
- Athletic training rooms
- Home-health organizations
- Clinician-managed home programs
- Facilities maintaining replacement inventory for existing Model 699 users
How to Apply the Electrodes
Follow the electrotherapy device manual, clinician instructions, and electrode packaging.
General application steps
- Turn the stimulator off and reduce every channel to zero.
- Inspect the electrode, lead wire, and connector.
- Clean and dry the treatment area.
- Remove lotion, oil, perspiration, and debris.
- Connect the lead-wire pin firmly to the side connector.
- Lift the electrode from its liner by the foam edge.
- Avoid pulling on the electrical connection.
- Apply the entire gel surface to intact skin.
- Press the edges down to obtain complete contact.
- Turn on the stimulator.
- Increase the intensity slowly.
- Stop for sharp, burning, painful, or irregular stimulation.
Complete Skin Contact Matters
The full electrode surface should remain in contact with the skin.
Poor contact can result from:
- Dry or worn conductive gel
- A lifted corner or edge
- Hair beneath the pad
- Lotion or oil on the skin
- Perspiration
- A damaged side-pin connector
- Excessive movement
- Placement over an uneven surface
- A pad that is too large or too small for the area
A concentrated stinging sensation beneath one portion of the electrode may indicate incomplete contact. Turn the device off before inspecting or repositioning the pad.
Reuse and Patient Assignment
The Model 699 is reusable, and the FDA record’s structured data does not designate it as a single-use product. Reusable electrodes should nevertheless be assigned to one patient only and maintained according to the package directions.
Do not share electrodes between patients.
Electrode life varies with:
- Skin preparation
- Skin oil and perspiration
- Body hair
- Treatment location
- Frequency of application
- Storage conditions
- Handling technique
- Gel condition
- Exposure to heat or air
Replace an electrode when it no longer provides secure, even contact.
Electrode Care and Storage
| Care step | Why it matters |
|---|---|
| Apply only to clean, dry skin | Helps preserve gel adhesion |
| Avoid touching the conductive gel | Reduces contamination and loss of tack |
| Remove the pad from an edge | Helps prevent connector damage |
| Do not pull on the side connector | Protects the electrical connection |
| Return the pad to its liner | Reduces exposure to air |
| Seal the package after use | Helps slow gel drying |
| Keep pads away from excessive heat | Protects foam and gel |
| Do not fold the electrode | Helps prevent conductor or backing damage |
| Assign pads to one patient | Supports hygiene |
| Replace damaged pads | Promotes more consistent stimulation |
Do not add water, conductive gel, adhesive spray, or another substance unless the electrode manufacturer expressly permits it.
When Should Model 699 Electrodes Be Replaced?
Replace an electrode when:
- It repeatedly lifts from the skin
- The gel has dried
- Adhesion cannot be restored through permitted care
- Stimulation feels sharp or uneven
- The foam is torn
- The electrode has become permanently folded
- The conductive layer appears damaged
- The side-pin connection has loosened
- The electrode produces intermittent output
- The pad has become contaminated
- The electrode has been used by another person
A visibly intact pad may still need replacement when its stimulation or adhesion becomes inconsistent.
Uni-Patch Model 699 vs. Balego 2-Inch Square Electrodes
| Feature | Uni-Patch Model 699 EC89455 | Balego® TENS/NMES/FES Electrodes |
|---|---|---|
| Size | 1.75 × 1.75 inches | 2 × 2 inches |
| Package quantity | 40 | 4 |
| Backing | Soft foam | Flexible spun-lace |
| Conductive contact | Reinforced solid gel | 0.040-inch reusable hydrogel |
| Conductive layer | Product described as conductive solid-gel electrode | Carbon-film conductor |
| Connection | Side pin | Soft-molded pigtail/socket |
| Country of manufacture | Verify current package | Made in the USA using American-made raw materials |
| Prescription status | FDA record indicates Rx | Follow exact product labeling and device requirements |
| Best fit | Existing Model 699 users, compact placement, bulk quantity | General-purpose current replacement pad in multiple sizes |
Choose Model 699 when the smaller footprint, EC89455 side-pin connector, or exact legacy product is required.
Choose Balego electrodes when a currently supported, American-made pigtail/socket pad with multiple size options is preferred. Balego’s electrodes are offered in 2-inch square, 2-inch round, 2 × 3.5-inch rectangle, 2.75-inch round, and 1.25-inch round sizes.
Model 699 vs. Uni-Patch R Series
| Feature | Model 699 Softy | Uni-Patch R Series Re-Ply® |
|---|---|---|
| Standard square size | 1.75 × 1.75 inches | 2 × 2 inches |
| Backing | Soft foam | Soft tricot |
| Hydrogel | Reinforced conductive solid gel | 0.025-inch hydrogel |
| Connection | Side pin | Pigtail / pin-compatible socket |
| Package | 40 electrodes | 4 electrodes |
| Shape choices | This page offers one compact square | Square, round, rectangular, oval, and larger round options |
| Best fit | Exact compact Model 699 replacement | Everyday reusable electrodes with broader size selection |
The R Series is a better choice when the buyer wants several shapes and sizes, a conventional pigtail connector, and smaller four-electrode retail packages.
Model 699 vs. Uni-Patch Classic Electrodes
| Feature | Model 699 Softy | Uni-Patch Classic Electrodes |
|---|---|---|
| Backing | Soft foam | Soft foam |
| Conductive system | Reinforced conductive solid gel | Silver ink/carbon film conductor |
| Hydrogel | Solid conductive gel | Aloe hydrogel |
| Square size | 1.75 inches | 2 inches |
| Connection | Side pin | Pigtail/socket |
| Package | 40 electrodes | 4 electrodes |
| Additional sizes | Not on this page | 2 × 4 oval, 4 × 2 rectangle, and 2.75-inch round |
| Best fit | Compact side-pin replacement | Comfort-focused aloe hydrogel and broader size selection |
Classic electrodes are preferable when aloe hydrogel, a silver/carbon conductive layer, or larger pad shapes are desired.
Model 699 vs. Tab-Style Electrodes
| Feature | Model 699 | Uni-Tab® Electrodes |
|---|---|---|
| Connection | Side pin | Flat tab |
| Lead requirement | Compatible pin lead | Compatible tab clip or adapter |
| Shape | Compact square | Multiple tab-style sizes |
| Reusable | The product listing says "reusable." | Depends on exact Uni-Tab labeling |
| Best fit | Existing pin-compatible setup | Devices and lead wires designed for tab electrodes |
A tab lead cannot attach directly to Model 699 unless a compatible adapter has been specifically approved. Balego’s connector guide emphasizes matching the electrode type to the device and lead-wire system. (Balego)
Which Electrode Should You Choose?
| Customer requirement | Recommended Balego product |
|---|---|
| Exact EC89455 replacement | Uni-Patch Model 699 |
| Compact 1.75-inch square footprint | Uni-Patch Model 699 |
| Side-pin electrode connection | Uni-Patch Model 699 |
| Forty-electrode bulk package | Model 699 or InTENSity 40-pack, depending on connector |
| Made-in-USA general-purpose pad | Balego® TENS/NMES/FES Electrodes |
| Soft-tricot Uni-Patch pad | Uni-Patch R Series |
| Aloe hydrogel and soft foam | Uni-Patch Classic Electrodes |
| Premium silver current-distribution design | Uni-Patch Starburst Electrodes |
| Blue gel for sensitive-skin positioning | 696SS Superior Silver® Electrodes |
| Tab-style lead connection | Uni-Tab® Stimulating Electrodes |
Browse our complete electrotherapy electrode collection for additional sizes, shapes, connector styles, and package quantities.
Customers who require Model 699 should confirm the following:
- That EC89455 is the exact connector required
- The quantity needed for an ongoing program
- Whether a future substitute is acceptable
- Which current Balego electrode most closely matches the device and treatment setup
Balego should present the product as remaining or legacy inventory if Cardinal Health confirms that the item is no longer manufactured.
Latex Information
The FDA UDI record does not identify EC89455 as required to carry a natural-rubber-latex warning, but it also does not identify the electrode as “not made with natural rubber latex.” Balego should therefore avoid an unqualified “latex-free” claim unless that exact wording appears on the current package.
Customers with a known latex allergy should verify the current product label before use.
Safety Information
Use Model 699 only with a compatible electrotherapy device and according to the device manual, electrode labeling, and a healthcare professional’s instructions.
Do not apply stimulation:
- Across the chest
- Through the head
- Over the eyes
- On the front or sides of the neck
- Over broken, infected, inflamed, or significantly irritated skin
- Over an area with severely impaired sensation
- In another location prohibited by the electrotherapy device manual
Do not use electrotherapy with a pacemaker, implanted defibrillator, or another implanted electronic device unless specifically cleared by the relevant medical specialist and device manufacturer.
Stop the session for:
- Burning
- Sharp or painful stimulation
- Persistent skin irritation
- Blistering
- Worsening symptoms
- Unexpected muscle movement
- Intermittent output caused by a damaged pad or lead wire
Richmar’s electrode instructions emphasize using self-adhesive electrodes according to the stimulator instructions and applying them only to sites selected by the healthcare professional.
Final Product Summary
Choose Uni-Patch Softy Model 699 EC89455 electrodes when the treatment setup requires the following:
- The exact Model 699 electrode
- A compact 1.75-inch square pad
- A side-pin connection
- Soft-foam construction
- Reinforced conductive solid gel
- A self-adhering reusable electrode
- A bulk package of 40
- Compatibility with a clinician-directed TENS, NMES, EMS, or FES system
Confirm the connector before ordering. EC89455 is not interchangeable with snap, tab, or standard pigtail electrodes merely because the pads have a similar size.
For currently supported replacement-pad options, browse Balego Electrotherapy Electrodes or compare Balego electrodes made in the USA.
Reviews
Rating Snapshot
No reviews yet — be the first to share your thoughts.
FAQs
What is the Uni-Patch Model 699 electrode?
It is a compact, self-adhering electrotherapy electrode with soft-foam construction, reinforced conductive solid gel, and a side-pin connector.
What is the manufacturer's item number?
EC89455.
What size is each electrode?
Each electrode measures 1.75 × 1.75 inches, or approximately 4.45 × 4.45 cm.
How many electrodes are included?
The package contains 40 electrodes.
Is the product a package of 40 pads or 40 four-packs?
It is 40 electrodes total. Balego should verify the exact inner-pouch configuration before describing how the 40 pads are grouped.
Are these electrodes reusable?
The Cardinal Health at-Home listing describes them as reusable and self-adhering. They should be assigned to one patient and replaced when adhesion or stimulation becomes unreliable.
Are Model 699 electrodes for TENS only?
No. The product listing identifies them for compatible TENS, NMES, and FES systems. They may also be described as EMS electrodes when the compatible muscle-stimulation device uses the same connector and electrode specifications.
Is EC89455 a pin or snap electrode?
EC89455 is the side-pin version. Please avoid ordering it when a snap electrode is required.
Does the pad have a pigtail wire?
No conventional external pigtail is described. The lead-wire pin attaches at the side connection on the pad.
Will these pads fit my TENS unit?
Only when the unit’s lead-wire pin and electrode requirements match EC89455. Compare the existing electrode connector or consult the device manufacturer.
Are these standard 2 mm electrodes?
The available authoritative EC89455 documentation identifies a side-pin connection but does not specify a universal 2 mm dimension. Balego should not publish “2 mm” unless confirmed from the current package or manufacturer.
Are the electrodes sterile?
No. FDA’s UDI record identifies EC89455 as nonsterile.
Are these electrodes prescription-only?
Yes. The FDA UDI record identifies EC89455 as prescription use and not OTC.
Are these electrodes latex-free?
The FDA record does not show a required latex warning, but it also does not label the product “not made with natural rubber latex.” Check the current package before making or relying on a latex-free claim.
Can multiple patients share the same electrodes?
No. Reusable self-adhesive electrodes should be assigned to one patient.
Can extra conductive gel be added?
Do not add conductive gel, adhesive spray, water, or another substance unless the electrode instructions specifically permit it.
How should the pads be stored?
Return the pads to their liner, seal them in their package, and protect them from air, heat, dirt, and moisture between sessions.
Why does the stimulation feel sharp?
Possible causes include a dry gel surface, lifted edge, incomplete skin contact, damaged connector, excessive intensity, or an electrode that needs replacement.
Is Model 699 discontinued?
The FDA's UDI record states that commercial distribution of EC89455 ended December 31, 2025. Balego currently has inventory, but future availability may be limited.
What is a good current alternative?
The best alternative depends on the connector and size. Compare Balego® TENS/NMES/FES Electrodes, Uni-Patch R Series, Classic Electrodes, and the InTENSity 2-Inch Square 40-Pack.