
Trivarion Iontophoresis Delivery Kits | 12/Box | ActivaDose II Compatible
In stock
🛡 Authorized Dealer - Authentic Products & Manufacturer Warranty
💲Price Match Guarantee
🚚 FREE & FAST Shipping
◆ Easy, Secure Checkout
💬Questions? Contact Our Product Specialists
About Trivarion Iontophoresis Delivery Kits | 12/Box | ActivaDose II Compatible
The Trivarion® Iontophoresis Delivery Kit is a professional iontophoresis electrode system designed for clinician-directed drug-delivery treatments using a compatible dose controller, such as the ActivaDose® II Iontophoresis Dose Controller. Each box includes 12 individually packaged treatment kits, and each kit contains one active delivery electrode, one return electrode, and one alcohol prep pad.
Trivarion® electrodes are especially useful when standard flat iontophoresis electrodes may not conform well to the treatment area. Their flexible, form-fitting design improves contact on curved or uneven anatomical sites, including the elbow, shoulder, knee, finger, knuckle, Achilles tendon, and carpal tunnel region.
For more iontophoresis supplies, browse our Iontophoresis collection, compare Ionto4™ Iontophoresis Electrodes, or review our clinical education hub: Iontophoresis Frequently Asked Questions.
Quick Product Summary
| Feature | Details |
|---|---|
| Product | Trivarion® Iontophoresis Delivery Kit |
| Balego Ref | TRIVARION-IONTOPHORESIS |
| Starting SKU | NC89180B |
| Package size | 12 individually packaged kits per box |
| Kit contents | Active delivery electrode, return electrode, alcohol prep pad |
| Size options | Small 1.5 cc, Medium 2.0 cc, Butterfly 2.0 cc, Large 3.5 cc |
| Dose capacity | Up to 80 mA·min |
| Technology | Carbon-Ag/AgCl electrode technology |
| Controller compatibility | Designed for use with the ActivaDose® II Controller |
| Gel requirement | No additional hydrogel required |
| Latex status | Not made with natural rubber latex |
| Best for | Professional iontophoresis treatment of curved or uneven areas |
| Balego category | Iontophoresis |
Why Choose Trivarion® Iontophoresis Electrodes?
Trivarion® is designed for clinicians who need a controller-based iontophoresis electrode that conforms better to difficult body contours. The electrode shape, absorbent internal matrix, and large adhesive surface area help support consistent contact during treatment.
| Benefit | Why It Matters |
|---|---|
| Flexible, form-fitting shape | Helps conform to curved, uneven, or smaller anatomical areas |
| Carbon-Ag/AgCl technology | Supports stable electrical performance during iontophoresis |
| Up to 80 mA·min delivery | Matches common controller-based iontophoresis dose workflows |
| Highly absorbent drug matrix | Helps hold the medication or solution evenly during delivery |
| Large adhesive surface area | Helps reduce pad movement during treatment |
| No additional hydrogel required | Simplifies setup and reduces mess |
| Multiple size options | Lets clinicians match fill volume and shape to the treatment area |
| Individually packaged kits | Convenient for clinics, athletic training rooms, and treatment carts |
| Not made with natural rubber latex | Useful for facilities managing latex exposure concerns |
Size Options and Best Uses
| Option | Fill Volume | Best For | Typical Fit |
|---|---|---|---|
| Small | 1.5cc | Smaller or more targeted treatment areas | Finger, knuckle, wrist, small tendon areas |
| Medium | 2.0 cc | General-purpose treatment areas | Elbow, shoulder, knee, wrist, ankle |
| Butterfly | 2.0 cc | Irregular or highly contoured areas | Achilles tendon, carpal tunnel area, curved joints |
| Large | 3.5cc | Larger treatment sites or higher fill-volume needs | Knee, shoulder, hip-region soft tissue, larger tendon or muscle areas |
The best size depends on the treatment area, medication volume, clinician protocol, skin surface, and controller settings.
What Comes in Each Trivarion® Kit?
Each individually packaged kit is designed to give the clinician the main disposable components needed for a controller-based iontophoresis treatment.
| Included Component | Purpose |
|---|---|
| Active delivery electrode | Holds the medication or solution and delivers ions during treatment |
| Return electrode | Completes the electrical circuit and helps support treatment comfort |
| Alcohol prep pad | Used to clean the skin before electrode placement |
Medication is not included unless specifically stated by the product listing or clinical protocol. Iontophoresis medication selection, polarity, dose, and treatment parameters should be determined by the prescribing clinician.
Trivarion® vs. Ionto4™ vs. Balego Buffered Iontophoresis Electrodes
| Product | Best For | Key Difference |
|---|---|---|
| Trivarion® Iontophoresis Delivery Kit | Uneven or curved treatment areas where form-fitting contact is important | Unique shape options, including Butterfly, with 1.5 cc–3.5 cc volumes |
| Ionto4™ Iontophoresis Electrodes | Traditional single-use drug-delivery electrode workflows | Available in square and butterfly options with up to 4.0 cc volume |
| Balego Iontophoresis Electrode Kit | Clinics needing buffered return electrode kits | Ag/AgCl drug electrode plus buffered return electrode and two alcohol prep pads |
| ActivaDose® II Dose Controller | Clinics needing the reusable dose-control unit | Controller used with compatible wired iontophoresis electrodes |
| IontoPATCH® Iontophoresis Patches | Self-contained patch delivery without external wires | Wearable patch format; no external controller required |
| ACTIVApatch® Iontophoresis Patches | Self-contained wearable patch options with different delivery times | Includes IntelliDose™, IontoGo™ 4.0, and IontoGo™ 12.0 options |
Controller-Based Electrodes vs. Self-Contained Iontophoresis Patches
Trivarion® is a controller-based iontophoresis electrode kit. It is different from self-contained wearable iontophoresis patches.
| Feature | Trivarion® Delivery Kit | Self-Contained IontoPatch® / ACTIVApatch® |
|---|---|---|
| Power source | External controller, such as ActivaDose® II | Built into the patch |
| Wires required | Yes | No |
| Best setting | In-clinic, clinician-supervised treatment | Clinic-applied wearable treatment |
| Dose control | Set through the controller | Built into the patch design |
| Electrode shape options | Small, Medium, Butterfly, Large | Product-dependent |
| Treatment area fit | Strong option for uneven surfaces | Strong option for wearable convenience |
| Medication included? | No | No |
| Best buyer | Clinics that prefer controller-based dosing | Clinics that want fewer setup steps and no controller |
For a deeper comparison of wearable patch formats, read IontoPatch vs. ACTIVApatch: Which Iontophoresis Patch Is the Better Buy?.
Why Electrode Shape Matters in Iontophoresis
Iontophoresis depends on consistent contact between the skin, electrode, medication matrix, and return electrode. On curved or uneven areas, flat electrodes may lift, wrinkle, or fail to maintain uniform contact.
| Treatment Area Challenge | How Trivarion® Helps |
|---|---|
| Curved joints | A flexible shape conforms better than a rigid flat pad |
| Tendons and smaller areas | Small and Butterfly options help target contoured anatomy |
| Areas with movement | A larger adhesive surface helps reduce pad shifting |
| Uneven skin surfaces | A form-fitting design helps improve contact |
| Need for cleaner setup | No additional hydrogel required |
| Need for volume selection | 1.5cc, 2.0cc, and 3.5cc options support different fill needs |
Best Uses by Setting
| Setting | How Trivarion® Fits |
|---|---|
| Physical therapy clinics | Controller-based iontophoresis for clinician-directed drug-delivery workflows |
| Sports medicine | Useful for tendon, joint, and soft-tissue areas where electrode fit matters |
| Athletic training rooms | Individually packaged kits work well for treatment carts and team settings |
| Orthopedic rehab | Helpful for clinician-directed localized medication delivery programs |
| Hand therapy | Small and Butterfly options can fit fingers, knuckles, wrists, and carpal tunnel regions |
| Chiropractic rehab | Fits clinics that use iontophoresis as an adjunct to broader care plans |
| Multi-site rehab departments | Boxed 12-kit packaging supports standardized clinic inventory |
Common Treatment-Area Fit Guide
| Treatment Area | Suggested Trivarion® Option | Why |
|---|---|---|
| Finger or knuckle | Small 1.5cc | Smaller fill volume and compact placement |
| Wrist or carpal tunnel region | Small 1.5 cc or Butterfly 2.0 cc | Better conformity around narrow or curved surfaces |
| Elbow | Medium 2.0cc or Butterfly 2.0cc | Works well around curved anatomy |
| Achilles tendon | Butterfly 2.0 cc | The butterfly shape can conform to tendon contours |
| Shoulder | Medium 2.0 cc or Large 3.5 cc | Choose based on surface area and medication volume |
| Knee | Medium 2.0 cc or Large 3.5 cc | Larger options help cover broader areas |
| Larger soft-tissue region | Large 3.5cc | Higher fill volume and larger treatment area |
How Trivarion® Fits with ActivaDose® II
Trivarion® electrodes are designed for use with the ActivaDose® II Iontophoresis Dose Controller. The controller-based workflow allows a clinician to set dose in mA·min, adjust current, and monitor treatment delivery.
| Workflow Step | Clinical Consideration |
|---|---|
| 1. Confirm prescription and medication | Medication choice, polarity, and dose should come from the prescribing clinician |
| 2. Choose electrode size | Match fill volume and shape to the treatment area |
| 3. Prepare the skin | Use the included alcohol prep pad as directed |
| 4. Fill the active electrode | Load the prescribed medication or solution according to instructions |
| 5. Place active and return electrodes | Follow polarity, spacing, and device instructions |
| 6. Connect to controller | Use the correct lead polarity for the prescribed ion |
| 7. Set dose and current | Follow the prescribed mA·min dose and patient tolerance |
| 8. Monitor treatment | Watch skin response, comfort, lead connection, and controller status |
| 9. Remove and inspect | Check skin after treatment and document response |
For setup support, review Iontophoresis Electrodes—Directions for Use.
Product Description
The Trivarion® Iontophoresis Delivery Kit is a professional single-use iontophoresis electrode kit designed for use with the ActivaDose® II Controller. Each box includes 12 individually wrapped treatment kits, and each kit includes one active delivery electrode, one return electrode, and one alcohol prep pad.
Trivarion® electrodes are built with carbon-Ag/AgCl technology, a highly absorbent internal drug matrix, and a large adhesive surface area. Their flexible, form-fitting design helps improve contact on curved and uneven treatment areas where standard flat electrodes may be difficult to apply.
Available in small 1.5cc, medium 2.0cc, butterfly 2.0cc, and large 3.5cc sizes, Trivarion® gives clinicians flexible options for different treatment regions, medication volumes, and patient anatomy. Choose Trivarion® when your clinic needs a controller-based iontophoresis electrode kit that conforms well to difficult treatment sites and does not require added hydrogel.
For related options, compare Ionto4™ Iontophoresis Electrodes, Balego Iontophoresis Electrode Kits, IontoPATCH® Iontophoresis Patches, and ACTIVApatch® Iontophoresis Patches.
Safety and Use Notes
| Safety Topic | Guidance |
|---|---|
| Professional use | Use under the direction of a qualified healthcare professional |
| Medication not included | Medication or solution must be supplied separately and prescribed appropriately |
| Polarity matters | Match medication polarity to the correct electrode lead |
| Dose matters | Follow the prescribed mA·min dose and controller instructions |
| Skin inspection | Do not apply over broken, irritated, infected, or damaged skin unless directed by a clinician |
| Sensation changes | Use caution with reduced sensation, neuropathy, poor circulation, or fragile skin |
| Implanted devices | Screen for pacemakers, implanted stimulators, and other contraindications |
| Pregnancy or high-risk conditions | Use only with medical guidance |
| Single-use kit | Do not reuse disposable treatment kits |
| Skin reaction | Stop and evaluate if burning, blistering, severe redness, rash, pain, or unusual symptoms occur |
Reviews
Rating Snapshot
No reviews yet — be the first to share your thoughts.
FAQs
What is the Trivarion® Iontophoresis Delivery Kit?
Trivarion® is a single-use iontophoresis electrode kit designed for clinician-directed drug-delivery treatments using a compatible iontophoresis dose controller such as ActivaDose® II.
How many kits come in each box?
Each box contains 12 individually packaged treatment kits.
What comes in each kit?
Each kit includes one active delivery electrode, one return electrode, and one alcohol prep pad.
What sizes are available?
Balego lists four size options: small 1.5cc, medium 2.0cc, butterfly 2.0cc, and large 3.5cc.
Which Trivarion® size should I choose?
Choose Small 1.5 cc for compact or targeted areas; Medium 2.0 cc for general use; Butterfly 2.0 cc for curved or irregular areas such as the Achilles tendon or carpal tunnel region; and Large 3.5 cc for broader treatment areas.
Is Trivarion® compatible with ActivaDose® II?
Yes. Balego lists Trivarion® as designed for use with the ActivaDose® II Iontophoresis Dose Controller.
Does Trivarion® require added hydrogel?
No additional hydrogel is required. Trivarion® uses a highly absorbent drug matrix and large adhesive surface area.
Is medication included?
No. Medication is not included. The medication or solution should be selected and prescribed by the clinician according to the treatment plan.
What does 80 mA·min mean?
mA·min is the iontophoresis dose measurement. It equals current in milliamps multiplied by treatment time in minutes. For example, 4 mA for 20 minutes equals 80 mA·min.
Is Trivarion® the same as IontoPatch®?
No. Trivarion® is a controller-based electrode kit used with a device such as ActivaDose® II. IontoPATCH® is a self-contained wearable patch system that does not require an external controller.
Is Trivarion® made with natural rubber latex?
Balego lists Trivarion® materials as not made with natural rubber latex.
Who should buy Trivarion®?
Trivarion® is best for physical therapy clinics, sports medicine practices, hand therapy clinics, orthopedic rehab departments, athletic training rooms, and other professional settings using compatible iontophoresis controllers.
Trivarion iontophoresis, Trivarion delivery kit, Trivarion electrodes, iontophoresis delivery kit, iontophoresis electrodes, ActivaDose II electrodes, NC89180B, NC89181B, NC89182B, NC89183B, small 1.5 cc iontophoresis electrode, medium 2.0 cc iontophoresis electrode, butterfly 2.0 cc iontophoresis electrode, large 3.5 cc iontophoresis electrode, carbon Ag AgCl iontophoresis electrode, 80 mA-min iontophoresis, form-fitting iontophoresis electrode, iontophoresis kit 12 box, North Coast Medical Trivarion












