
VitalStim® Plus Electrotherapy & sEMG Biofeedback System
In stock
🛡 Authorized Dealer - Authentic Products & Manufacturer Warranty
💲Price Match Guarantee
🚚 FREE & FAST Shipping
◆ Easy, Secure Checkout
💬Questions? Contact Our Product Specialists
Chattanooga VitalStim® Plus Electrotherapy & sEMG Biofeedback System
The Chattanooga VitalStim Plus Electrotherapy System combines four-channel neuromuscular electrical stimulation with two-channel surface electromyography, or sEMG, for clinician-directed treatment of oral-pharyngeal dysfunction and dysphagia. It gives qualified healthcare professionals a single platform for electrical stimulation, muscle-activity biofeedback, triggered stimulation, patient education, and treatment documentation.
VitalStim Plus is designed specifically for swallowing rehabilitation rather than general-purpose TENS or portable muscle stimulation. Its treatment options include the dedicated VitalStim waveform, customizable VMS stimulation, standalone sEMG biofeedback, and sEMG-triggered stimulation. Bluetooth screen mirroring, an anatomical image library, instructional content, and exportable patient data help clinicians create an interactive therapy experience while tracking treatment performance.
For additional information about integrating NMES into rehabilitation settings, read our guide to long-term care rehabilitation modalities.
VitalStim Plus at a Glance
| Product detail | Specification |
|---|---|
| Product | VitalStim® Plus Electrotherapy and sEMG Biofeedback System |
| Manufacturer | Chattanooga / Enovis |
| Manufacturer SKU | 5923-3 |
| Primary application | Clinician-directed dysphagia and swallowing-muscle rehabilitation |
| Stimulation channels | Up to 4 independent channels |
| sEMG channels | Up to 2 channels |
| Treatment options | VitalStim, VMS, sEMG and sEMG-triggered stimulation |
| VitalStim output | Constant-current stimulation, 0–25 mA |
| Connectivity | Bluetooth connection and screen mirroring to a compatible computer or tablet |
| Data management | Store, display and export treatment information |
| Power | Four 1.5-volt AA batteries |
| Device weight | Approximately 0.75 lb. |
| Dimensions | 3.8 in. wide × 1.4 in. deep × 6.2 in. high |
| Intended user | Qualified healthcare professional |
| Regulatory status | Prescription professional device |
A Specialized System for Dysphagia Rehabilitation
VitalStim Plus is designed to support muscle re-education of the swallowing musculature. The system brings several complementary tools into one portable clinical device:
- Four-channel stimulation allows clinicians to apply stimulation through as many as four channels during a treatment session.
- Two-channel sEMG biofeedback measures voluntary muscle activity and converts it into visual and audible feedback.
- Threshold-triggered stimulation can begin stimulation after the patient reaches a clinician-selected sEMG target.
- Custom VMS protocols allow adjustment of frequency, pulse duration, work time, rest time, ramping, and channel sequencing.
- Patient education resources include an anatomical library and videos demonstrating selected swallowing exercises and electrode-placement options.
- Treatment documentation allows patient-session data to be stored, reviewed, and exported.
- Bluetooth screen mirroring can display treatment progress on a compatible computer or tablet, making biofeedback easier for both clinician and patient to view.
VitalStim Plus Treatment Modes
| Treatment mode | How it works | Clinical purpose |
|---|---|---|
| VitalStim | Delivers the dedicated VitalStim waveform through as many as four channels in co-contraction mode | Muscle re-education of swallowing musculature under qualified clinical supervision |
| VMS | Provides customizable symmetrical biphasic stimulation with adjustable treatment parameters and channel sequencing | Allows the clinician to build individualized stimulation protocols |
| sEMG | Measures voluntary muscle activity and displays visual and audible biofeedback | Helps patients recognize, practice, and repeat targeted muscle activity |
| sEMG + Triggered Stimulation | Monitors sEMG activity and initiates stimulation after a preset threshold is reached | Adds stimulation after the patient actively begins the exercise |
| Patient Data | Stores stimulation and sEMG treatment information | Supports progress review and clinical documentation |
| Anatomical Library | Displays dysphagia-related anatomy, pathology, and treatment images | Supports patient education and explanation of the therapy plan |
The system’s interface provides direct access to VitalStim, VMS, sEMG, sEMG plus stimulation, patient data, an anatomical library, and device utilities.
How sEMG Biofeedback Supports an Interactive Session
Surface electromyography measures the electrical activity produced during voluntary muscle contraction and relaxation. VitalStim Plus can display that activity on the device or a mirrored screen and convert it into audible feedback.
Instead of asking the patient to perform an exercise without objective feedback, the clinician can establish a target and show the patient how much activity is being generated. This can help structure repetitions, encourage active participation, and provide measurable treatment information.
During sEMG-triggered stimulation, the patient first attempts the prescribed swallowing exercise. When muscle activity reaches the selected threshold, the system changes to stimulation mode. The patient therefore initiates the activity rather than receiving stimulation without first attempting the movement.
VitalStim and VMS Waveform Specifications
| Parameter | VitalStim waveform | VMS waveform |
|---|---|---|
| Waveform type | Symmetrical square biphasic | Symmetrical biphasic |
| Output | Constant current | Constant current |
| Intensity range | 0–25 mA | 0–25 mA |
| Phase duration | 300 microseconds | Adjustable from 60 to 300 microseconds |
| Frequency | 80 pulses per second | Adjustable from 1–80 pulses per second |
| Channel mode | Co-contraction | Continuous, reciprocal or co-contraction |
| Cycle time | 57 seconds on, 1 second off | User-defined on and off times from 1–99 seconds |
| Ramp | 2 seconds | Adjustable from 0 to 3 seconds |
| Treatment time | 60 minutes | Adjustable from 1 to 240 minutes |
| Available channels | Channels 1, 2, 3, and/or 4 | Channels 1, 2, 3, and/or 4 |
Treatment parameters, electrode selection, electrode placement, patient screening, and treatment duration must be determined by a qualified practitioner following the manufacturer’s instructions and applicable professional requirements.
Built-In Patient Education and Treatment Tools
VitalStim Plus includes resources that can help clinicians explain the treatment process and keep patients engaged. Depending on the installed software and configuration, these resources include:
| Tool | Practical benefit |
|---|---|
| Swallowing-exercise videos | Demonstrate exercises such as the Masako exercise, Mendelsohn maneuver, and supraglottic maneuver |
| Electrode-placement resources | Provide quick access to manufacturer-provided placement information |
| Dysphagia anatomical library | Helps explain swallowing anatomy, pathology, and treatment concepts |
| Screen mirroring | Displays live activity on a larger computer or tablet screen |
| Visual and audible feedback | Gives the patient immediate information about muscle effort |
| Custom protocols | Lets the clinician save frequently used treatment configurations |
| Patient-data storage | Supports session review, progress tracking, and reporting |
Who Is VitalStim Plus Designed For?
VitalStim Plus may be appropriate for professional environments that provide medically directed dysphagia evaluation and rehabilitation, including:
- Speech-language pathology departments
- Dysphagia and swallowing clinics
- Hospitals and outpatient rehabilitation centers
- Skilled nursing and long-term care facilities
- Neurological rehabilitation programs
- Head-and-neck rehabilitation programs
- Academic and clinical training environments
VitalStim Plus is a professional healthcare product. VitalStim Therapy should be administered by appropriately trained clinicians who have completed the applicable certification process and who are working within their licensure, scope of practice, prescription requirements, and facility protocols.
VitalStim Plus vs. Other NMES Devices
VitalStim Plus should not be confused with a conventional portable NMES unit. General muscle stimulators may be appropriate for extremity muscle activation or other clinician-directed musculoskeletal programs, but they do not provide VitalStim’s dedicated dysphagia waveform, swallowing-focused interface, two-channel sEMG, threshold-triggered stimulation, anatomical library, or patient-data system.
Browse additional professional systems in our clinical electrotherapy collection, or compare portable options in the neuromuscular stimulation collection.
Standard VitalStim Plus Accessories
The manufacturer’s standard accessory list identifies the following components:
- Four color-coded snap lead wires for stimulation channels 1–4
- White sEMG reference lead wire
- Operator hand switch
- Lead-wire clips
- Device stand
- Stylus
- Protective rubber sleeve
- Battery door
Electrode style, size, placement, and compatibility are especially important for anterior-neck applications. Use only VitalStim electrodes and accessories specifically approved by the manufacturer and selected according to the prescribed clinical protocol. Contact Balego product support before ordering when compatibility is uncertain.
Technical Specifications
| Specification | VitalStim Plus |
|---|---|
| Width | 3.8 in. / 9.6 cm |
| Depth | 1.4 in. / 3.6 cm |
| Height | 6.2 in. / 16 cm |
| Weight | 0.75 lb. / 0.34 kg |
| Power input | 6 volts from four 1.5-volt AA batteries |
| Maximum patient output voltage | 70 volts |
| Maximum VitalStim intensity | 25 mA |
| sEMG measurement range | 0.2–2,000 microvolts RMS |
| sEMG sensitivity | 0.1 microvolt RMS |
| Stimulation channels | 4 |
| sEMG channels | 2 |
| Electrical classification | Type BF |
| Operating temperature | 41°F–104°F / 5°C–40°C |
| Manufacturer number | 5923-3 |
| Balego reference | VITALSTIM-PLUS |
Important Safety and Professional-Use Information
VitalStim Plus is a prescription professional device and is not intended as a consumer self-treatment unit. The practitioner must review the complete operator manual, indications, contraindications, warnings, precautions, electrode requirements, and treatment instructions before use.
Stimulation should not be applied over the carotid sinus, cancerous lesions in the treatment area, or swollen, infected, inflamed, or eruptive skin areas. Particular caution is required for patients with pacemakers or other implanted electronic devices, suspected cardiac conditions, epilepsy, impaired sensation, or other listed risk factors. Patient selection is especially important in the management of dysphagia.
Only manufacturer-recommended lead wires, electrodes, and accessories should be used. This summary does not replace the complete VitalStim Plus instructions for use, professional training, medical evaluation, or clinician judgment.
Order the VitalStim Plus System from Balego
The Chattanooga VitalStim Plus gives qualified dysphagia professionals a portable system for four-channel stimulation, two-channel sEMG biofeedback, triggered stimulation, patient engagement, and treatment documentation.
Order the VitalStim Plus Electrotherapy and sEMG Biofeedback System, SKU 5923-3, or contact Balego for assistance with product information, approved accessories, clinic purchasing, or compatibility questions.
Reviews
Rating Snapshot
No reviews yet — be the first to share your thoughts.
FAQs
What is the VitalStim Plus Electrotherapy System used for?
VitalStim Plus is a professional electrotherapy and sEMG biofeedback system designed for muscle re-education of the swallowing musculature in clinician-directed dysphagia rehabilitation. It combines a dedicated VitalStim waveform, customizable VMS stimulation, sEMG biofeedback, and sEMG-triggered stimulation.
How many channels does VitalStim Plus have?
The system provides up to four channels of electrical stimulation. Channels 1 and 2 may also be used for surface EMG measurement, giving the system two-channel sEMG capability.
What is the difference between sEMG and electrical stimulation?
sEMG measures electrical activity created by voluntary muscle contraction. Electrical stimulation delivers current through electrodes to activate targeted nerves and muscles. VitalStim Plus can use these separately or combine them so that stimulation begins when the patient reaches a selected sEMG threshold.
Can VitalStim Plus display treatment activity on a larger screen?
Yes. Bluetooth screen-mirroring technology can project live treatment activity to a compatible computer or tablet. This can make visual biofeedback easier to see and can support patient participation during prescribed exercises.
Can VitalStim Plus save patient treatment data?
Yes. Stimulation and sEMG treatment data can be stored, displayed, and exported to a computer for progress tracking and report generation. Clinicians must follow applicable patient-privacy and facility data-handling policies.
Is VitalStim Plus a TENS unit?
No. VitalStim Plus is a specialized NMES and sEMG biofeedback system for dysphagia rehabilitation. It does not provide conventional TENS, interferential, or Russian stimulation modes.
Can a patient purchase VitalStim Plus for unsupervised home treatment?
VitalStim Plus is a prescription professional device intended for use under the prescription and supervision of a licensed healthcare practitioner. It should not be positioned as a general consumer or unsupervised home-use stimulator.
Are VitalStim electrodes included?
The standard accessory list identifies the lead wires, sEMG reference lead, hand switch, stand, stylus, rubber sleeve, and battery door but does not identify treatment electrodes. Confirm the exact package contents and order approved VitalStim electrodes separately when required.
Can standard TENS electrodes be used with VitalStim Plus?
Only electrodes and accessories specifically recommended for VitalStim Plus should be used. Standard general-purpose TENS or NMES electrodes should not be assumed to be suitable for anterior-neck or dysphagia applications.









