Intelect Legend 2 and 4-channel combo SKU 81-5010 81-5011

Chattanooga Group

Chattanooga Intelect Legend 2 Combo | 2- or 4-Channel E-Stim + Ultrasound

Ref: INTELECT-LEGEND-2-COMBO

Category: Intelect® Legend 2

SKU: 81-5010

GTIN/UPC: 190446780601

$2,999.00
$5,799.00
5% OFF, Buy 2+
Channels

In stock

🛡 Authorized Dealer - Authentic Products & Manufacturer Warranty

💲Price Match Guarantee

🚚 FREE & FAST Shipping

◆ Easy, Secure Checkout

💬Questions? Contact Our Product Specialists

Chattanooga® Intelect® Legend 2 Combination Therapy System

The Chattanooga Intelect Legend 2 Combo is a professional clinical therapy system that combines electrical stimulation, therapeutic ultrasound, and ultrasound-plus-electrotherapy combination treatment into one modern platform.

Choose a two-channel configuration for standard clinical stimulation and combination-therapy workflows, or a four-channel configuration when the practice needs more electrotherapy outputs for broader, bilateral, or multiple treatment setups.

Both systems come with 12 electrotherapy waveforms, dual-frequency therapeutic ultrasound, a high-resolution 7-inch color touchscreen, suggested protocol settings, customizable parameters, and space for up to 12 home-screen treatment shortcuts. Chattanooga’s app-like interface is designed to help clinicians move quickly between treatment setup, protocol selection, anatomical education, and real-time treatment monitoring.

Professional-use notice: The Intelect Legend 2 is intended for use only under the prescription and supervision of a licensed medical practitioner. Treatment selection, waveform parameters, ultrasound dosage, electrode placement and patient monitoring must follow the current device manual, clinician training and facility procedures.

For compatible sound heads, carts, replacement lead wires, and probe accessories, shop Intelect Legend 2 Accessories.

Product highlights

  • Two- or four-channel clinical electrotherapy options
  • Therapeutic ultrasound
  • Ultrasound and electrical-stimulation combination therapy
  • 12 electrotherapy waveform choices
  • Chattanooga proprietary VMS waveform
  • Interferential and premodulated stimulation
  • Russian stimulation
  • High-volt stimulation
  • Microcurrent and direct-current options
  • 1 MHz and 3.3 MHz ultrasound
  • Standard 5 cm² ultrasound applicator
  • Optional 1, 2 and 10 cm² applicators
  • Improved ultrasound coupling detection and monitoring
  • High-resolution 7-inch color touchscreen
  • Suggested Protocol Settings menu
  • 2&Go home-screen shortcuts
  • Save as many as 12 preset or custom protocols to the home screen
  • High-resolution anatomical library
  • Custom waveform and parameter controls
  • Real-time treatment display
  • Onboard memory and software-update capability
  • Optional rechargeable battery
  • Integrated carrying handle
  • Optional magnetic therapy cart
  • Compatible standard and XL lead-wire kits
  • Optional high-volt probe kit

12 waveforms, a 7-inch touchscreen, SPS and 2&Go features, an optional battery and cart, dual-frequency ultrasound, and multiple applicator choices.

Quick specifications

SpecificationIntelect Legend 2 Combo
ManufacturerChattanooga / Enovis
Device typeProfessional electrotherapy, ultrasound and combination-therapy system
Model choicesTwo-channel or four-channel
Two-channel SKU81-5010
Four-channel SKU81-5011
Electrotherapy waveforms12
Ultrasound frequencies1 MHz and 3.3 MHz
Standard ultrasound applicator5 cm²
Optional applicators1, 2 and 10 cm²
Display7-inch high-resolution color touchscreen
Home-screen shortcutsUp to 12 preset or custom protocols
Suggested Protocol SettingsYes
Anatomical libraryYes
Ultrasound coupling monitoringYes
Combination therapyYes
Mains input100–240 VAC, 50/60 Hz, 1.0 A
BatteryOptional, sold separately
Therapy cartOptional, sold separately
U.S. useProfessional use under prescription and supervision

Two-channel vs. four-channel Intelect Legend 2

Feature2-Channel Combo4-Channel Combo
Manufacturer SKU81-501081-5011
Electrotherapy channels24
UltrasoundYesYes
Combination therapyYesYes
E-stim waveforms1212
Display7-inch touchscreen7-inch touchscreen
Standard sound head5 cm²5 cm²
Approximate weight6.8 lb8.2 lb
Approximate size14" × 13.4" × 5.9"14" × 13.4" × 7.5"
Best fitStandard treatment rooms and clinics where two e-stim channels are sufficientHigher-volume clinics needing additional outputs or larger placement flexibility
Lead-wire requirementChannels 1 and 2Channels 1–4
Relative costLowerHigher

The primary difference is electrotherapy channel capacity. Both configurations retain the Legend 2 software, waveform library, ultrasound system, and workflow tools.

Choose the two-channel system when:

  • Most clinic treatments use one or two electrode pairs.
  • The device will frequently be used for ultrasound or combination therapy.
  • Four simultaneous electrotherapy outputs are not routinely required.
  • A lower equipment cost is more important than maximum channel capacity.
  • The clinic is replacing a conventional two-channel combo system.
  • Treatment-room space and equipment weight are priorities.

Choose the four-channel system when:

  • The clinic regularly uses more than two electrotherapy channels.
  • Larger, bilateral or multi-region setups are common.
  • A high-volume rehabilitation department may share the device.
  • The additional channel capacity justifies the higher cost and larger enclosure.
  • Four-channel IFC, NMES, or other multi-output workflows are part of the practice.
  • The clinic wants to avoid replacing a two-channel unit later as treatment volume grows.

The 12 electrotherapy waveforms

WaveformGeneral professional workflow
VMSChattanooga muscle-stimulation waveform
VMS BurstBurst-format VMS stimulation
VMS FRVMS variation with additional frequency-related controls
InterferentialTraditional interferential-current workflows
PremodulatedTwo-electrode interferential-style stimulation
Asymmetric BiphasicSensory or motor stimulation depending on selected parameters
Symmetric BiphasicBiphasic stimulation with balanced phase geometry
High voltageHigh-voltage pulsed-current workflows
MicrocurrentVery-low-current professional protocols
RussianMedium-frequency burst muscle stimulation
HANAlternating-frequency stimulation waveform
Direct CurrentContinuous direct-current applications permitted by the labeling

This table identifies product capabilities rather than treatment recommendations. A qualified professional must select the waveform, intensity, frequency, pulse duration, duty cycle, polarity, and electrode placement.

Chattanooga VMS waveform

The VMS waveform is a muscle-stimulation option designed to support stronger contractions, reduced neural fatigue, and improved comfort compared with traditional Russian stimulation.

Chattanooga’s proprietary VMS waveform is designed to support efficient, comfortable muscle contractions while helping clinicians manage stimulation parameters and fatigue during professionally directed muscle-reeducation programs.

Therapeutic ultrasound

The Legend 2 Combo provides 1 MHz and 3.3 MHz therapeutic ultrasound through compatible pre-calibrated applicators.

Ultrasound featurePractical value
1 MHz frequencyProfessional ultrasound option generally associated with deeper treatment targets
3.3 MHz frequencyHigher-frequency options are generally selected for more superficial treatment targets
5 cm² applicator includedVersatile standard size for many routine treatment areas
1 cm² applicatorOptional choice for small, focused regions
2 cm² applicatorOptional small-to-medium sound head
10 cm² applicatorOptional choice for broader treatment regions
Coupling detectionHelps identify inadequate sound-head contact
Ergonomic applicatorDesigned for routine clinician handling
Combination modeAllows compatible ultrasound and e-stim workflows within one system

The Legend 2 sound heads are specific to the Legend 2 platform. Do not substitute an applicator for the Transport 2 merely because the size and frequency appear similar.

Shop compatible options on our Intelect Legend 2 accessories page.

What does “combination therapy” mean?

The system can be used in three principal ways:

Treatment formatDevice function
Electrotherapy aloneElectrical stimulation is delivered through compatible electrodes
Ultrasound aloneTherapeutic ultrasound is delivered through the selected applicator and ultrasound coupling gel
Combination therapyCompatible electrical stimulation and ultrasound are delivered in a coordinated professional workflow

Ultrasound and electrotherapy may be used independently or in combination. This capability distinguishes the Legend 2 Combo from an electrotherapy-only console such as the Richmar Quattro 2.5.

Workflow features

2&Go treatments

The clinician can place up to 12 preset or custom treatments directly on the home screen. Chattanooga describes the feature as allowing selected treatments to begin within two button presses.

This feature is best positioned as a shortcut system—not as a claim that every treatment requires only two actions from power-on to patient connection.

Suggested Protocol Settings

The SPS menu allows the clinician to select an indication and view suggested parameters without manually constructing every setting from the beginning.

Suggested Protocol Settings provide a structured starting point based on the selected indication. The treating professional remains responsible for reviewing and modifying every parameter based on the patient, prescription, treatment goal and response.

Anatomical library

The high-resolution anatomical library can support patient education and help clinicians explain treatment areas and selected pathologies.

It should not be described as

  • A diagnostic system
  • A replacement for medical imaging
  • An automated treatment recommendation engine
  • Proof that a displayed protocol is appropriate for every patient

Software updates

The system includes onboard memory and software-update capability. Free updates or new functionality should be described only when currently offered by Chattanooga and subject to its update policies.

Standard package

Current distributor information verifies the following for the two-channel model, SKU 81-5010:

Included itemQuantity or description
Intelect Legend 2 two-channel unit1
Nylatex wrap1
Channel 1/2 stimulation lead-wire kit1 kit
Carbon electrodes4
DURA-STICK PLUS 5 cm square electrodes4
Legend 2 - 5 cm² ultrasound applicator1
USB drive1
Power cord1
Package contents depend on the selected two- or four-channel configuration. Each system includes the Legend 2 console, a standard 5 cm² ultrasound applicator, electrotherapy accessories and power components. Confirm the current manufacturer packing list for exact accessory quantities.

Product comparison

Intelect Legend 2 vs. related Balego clinical systems

FeatureIntelect Legend 2 ComboIntelect Transport 2 ComboRichmar ComboCareRichmar Quattro 2.5
FormatAdvanced clinical combo consoleCompact portable comboCompact clinical comboClinical e-stim only
E-stim channels2 or 4224
UltrasoundYesYesYesNo
Ultrasound + e-stim comboYesYesYesNo
E-stim waveforms1255 principal waveform families5 waveform families
Ultrasound frequencies1 and 3.3 MHz1 and 3.3 MHz1 and 3 MHzNot applicable
Interface7-inch color touchscreenColor clinical interfaceGraphical LCDGraphical LCD with knobs
Home-screen shortcutsUp to 12Protocol memoryPresets and custom memoryPresets and custom programs
SPS indication menuYesMore streamlined workflowNo equivalent Legend 2 SPSNo equivalent Legend 2 SPS
Anatomical libraryYesMore limitedNoNo
Optional batteryYesYesNo internal battery listedNo
Optional cartMagnetic Legend 2 cartTransport 2 carts.Generic cart useGeneric cart use
Best fitClinics wanting the broadest waveform selection and modern touchscreen workflowMobile clinics and training rooms prioritizing portabilityClinics seeking strong value in a two-channel comboClinics needing four-channel e-stim without ultrasound

The Legend 2 provides 12 waveforms, while the Transport 2 Combo provides five core stimulation waveforms. ComboCare offers two-channel stimulation, ultrasound and combination therapy at a lower equipment cost, while Quattro 2.5 is intended for clinics that need four-channel stimulation but not therapeutic ultrasound.

Choose the Intelect Legend 2 when:

  • Your clinic needs electrotherapy and therapeutic ultrasound in one system.
  • A 7-inch touchscreen and modern clinical interface are priorities.
  • Twelve electrotherapy waveforms are useful.
  • Suggested protocol settings will improve workflow.
  • The anatomical library is useful for patient education.
  • Two- and four-channel configurations need to be available within one platform.
  • Optional cart and battery use are valuable.
  • Multiple ultrasound applicator sizes are required.
  • The practice expects to use both routine and specialized waveforms.

Electrodes, gel and replacement accessories

SupplyWhen it is neededBalego link
Legend 2 ultrasound applicatorsReplace or add another treatment-head sizeLegend 2 Accessories
Channel lead-wire kitsReplacement or backup stimulation leadsLegend 2 Accessories
Magnetic therapy cartRoom-to-room movement and storageLegend 2 Accessories
HV probe kitCompatible high-volt probe treatmentsLegend 2 Accessories
Clinic electrode supplyRoutine adhesive-pad replacementDURA-STICK PLUS Electrodes
Alternative electrodesCompare sizes, shapes and backing materialsElectrotherapy Electrodes
Ultrasound contact mediumRequired for acoustic couplingUltrasound Therapy and Contact Media

Do not add conductive electrode gel to pre-gelled self-adhering pads unless the electrode instructions expressly permit it. Therapeutic ultrasound requires an appropriate acoustic coupling gel; electrode gels and ultrasound gels should not automatically be treated as interchangeable.

Basic clinical setup overview

Keep this concise on the product page and rely on the current manual for operational detail.

  1. Confirm the prescription, selected modality, and patient suitability.
  2. Inspect the system, power components, applicator, lead wires, and electrodes.
  3. Connect the required accessories before beginning treatment.
  4. Select the two- or four-channel electrotherapy configuration being used.
  5. Choose electrotherapy, ultrasound, or combination mode.
  6. Use an SPS protocol, a saved shortcut, or manually selected parameters.
  7. Review and modify all suggested parameters.
  8. Prepare the skin or ultrasound treatment area.
  9. Apply appropriately sized electrodes or ultrasound coupling gel.
  10. Begin at the prescribed output and monitor the patient throughout treatment.
  11. Stop treatment immediately for pain, burning, unexpected contraction, dizziness, poor ultrasound coupling, or another adverse response.
  12. Inspect the skin and equipment after treatment.
  13. Clean and store accessories according to the manual.

Professional-use and safety notes

Safety topicPage guidance
Professional supervisionUse only under prescription and licensed supervision
Suggested protocolsStarting points only; clinician review is required
ElectrodesUse compatible sizes, complete contact and intact lead wires
Ultrasound gelUse an approved coupling medium
Applicator movementFollow the manual for movement, contact and treatment technique
Coupling detectionRespond to poor-coupling alerts rather than bypassing them
Implanted devicesFollow all contraindications and precautions
PregnancyFollow all electrotherapy and ultrasound restrictions in the manual
Thrombosis riskUse only according to the labeled indication and medical direction
Skin integrityInspect before, during and after stimulation
Unexplained painDo not use to independently diagnose or treat an undiagnosed condition
CleaningFollow manufacturer-compatible cleaning and disinfection procedures
AccessoriesUse the correct Legend 2 sound heads, leads and power accessories

Additional Recommended Resources

Reviews

Rating Snapshot

5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Stars
0

Overall Rating

—

0 Reviews

Review this Product

Sign in to write a review.

No reviews yet — be the first to share your thoughts.

FAQs

What is the Intelect Legend 2 Combo?

It is a professional combination-therapy system providing clinical electrical stimulation, therapeutic ultrasound, and compatible ultrasound-plus-e-stim treatment.

Is it available with two or four channels?

Yes. The two-channel system is SKU 81-5010, and the four-channel system is SKU 81-5011.

Do both versions include ultrasound?

Yes. Both configurations provide therapeutic ultrasound and electrotherapy/ultrasound combination capability.

How many electrotherapy waveforms are included?

Twelve: VMS, VMS Burst, VMS FR, Interferential, Premodulated, Asymmetric Biphasic, Symmetric Biphasic, High Volt, Microcurrent, Russian, HAN, and Direct Current.

What ultrasound frequencies are available?

1 MHz and 3.3 MHz operation.

Which ultrasound applicator is included?

The standard package includes a 5 cm² Legend 2 ultrasound applicator. Optional 1, 2, and 10 cm² sound heads are available.

Are Legend 2 and Transport 2 applicators interchangeable?

No. They are separate accessory families. Order a sound head specifically identified for the Legend 2.

What is 2&Go?

It is a home-screen shortcut feature that lets the clinician save as many as 12 preset or custom protocols for faster access. Chattanooga describes selected treatments as accessible within two button presses.

What is SPS?

Suggested Protocol Settings provides a starting setup based on a selected indication. The clinician must still review every parameter and confirm that it is suitable for the patient.

Does SPS prescribe or diagnose a condition?

No. It is a clinical setup aid, not an autonomous diagnostic or prescribing system.

What does the anatomical library do?

It provides visual information that can help clinicians explain anatomy, pathologies, and treatments. It does not replace diagnosis, imaging, or professional judgment.

Can ultrasound and electrical stimulation be used together?

Yes. The system supports independent electrotherapy, independent ultrasound, and compatible combination treatment.

Is an optional battery available?

Battery-powered operation as an available option. The battery is not included in the standard system.

Is the therapy cart included?

No. The magnetic Legend 2 cart is optional and can be purchased through our Legend 2 Accessories page.

What is the difference between the 2CH and 4CH systems?

The four-channel version provides two additional stimulation outputs and has a larger, heavier enclosure. The ultrasound capabilities, waveform library, and principal interface features remain consistent.

Is it suitable for home use?

It is a professional system intended for prescription and licensed supervision, not a home electrotherapy product for general consumers.

Does it include TENS and NMES?

It includes multiple sensory- and motor-level electrical-stimulation waveforms that support TENS- and NMES-type workflows directed by professionals.

Does it include interferential stimulation?

Yes. It includes both traditional interferential and premodulated waveforms.

Does it include Russian stimulation?

Yes.

Does it include microcurrent?

Yes.

Does it include direct current?

Yes. Direct-current applications should be performed only according to the manual, labeling, and appropriate professional protocols.

Which model is best for a small clinic?

The two-channel model is generally the better value when two outputs are sufficient. The four-channel model is appropriate when the practice regularly needs additional stimulation channels.

Ask your Question