Kendall Medi-Trace 200 Series Foam ECG Monitoring Electrodes
Ref: MEDI-TRACE-200-SERIES
Category: Monitoring EKG/ECG Electrodes
SKU: 31078135
GTIN/UPC: 50192253017241
In stock
🛡 Authorized Dealer - Authentic Products & Manufacturer Warranty
💲Price Match Guarantee
🚚 FREE & FAST Shipping
◆ Easy, Secure Checkout
💬Questions? Contact Our Product Specialists
Kendall™ Medi-Trace™ 200 Series Foam ECG/EKG Monitoring Electrodes
The Kendall Medi-Trace 200 Series is a compact, cost-effective adult ECG/EKG monitoring electrode designed for lower- to mid-acuity patient-care environments. Its smaller teardrop profile supports convenient placement when space is limited, while the flexible foam substrate conforms to body contours and helps repel fluids.
Each disposable electrode incorporates Cardinal Health’s proprietary conductive adhesive hydrogel. The gel provides adhesion and the conductive skin interface needed for reliable cardiac monitoring, so no separate ECG gel is required. A standard snap connector attaches to compatible patient-monitoring lead wires.
The 200 Series is commonly selected for general inpatient units, medical-surgical floors, observation units, outpatient monitoring areas, and other routine adult cardiac-monitoring applications. Cardinal Health classifies the family within its Value Choice collection.
Product highlights
- General-purpose adult ECG/EKG monitoring electrode
- Compact 1.44-inch teardrop profile
- Small footprint for convenient lead placement
- Flexible foam backing
- Fluid-repellent substrate
- Proprietary conductive adhesive hydrogel
- Standard snap-style lead connection
- Designed for clear, reliable ECG tracings
- The teardrop shape supports easier handling and removal
- Disposable, single-patient-use format
- Non-radiolucent construction
- Four pouch and case configurations
- Appropriate for lower- to mid-acuity monitoring environments
- Manufactured for the Cardinal Health Kendall portfolio
The 200 Series is a non-radiolucent adult monitoring electrode that has a 1.44-inch footprint, foam substrate, teardrop shape, and conductive adhesive hydrogel.
Quick specifications
| Specification | Medi-Trace 200 Series details |
|---|---|
| Brand | Kendall™ Medi-Trace™ |
| Current portfolio | Cardinal Health |
| Product family | 200 Series |
| Models included | 200, 230, 233, and 235 |
| Product type | Disposable ECG/EKG monitoring electrode |
| Patient category | Adult |
| Primary application | General cardiac monitoring |
| Acuity positioning | Lower- to mid-acuity environments |
| Backing | Conformable foam |
| Fluid resistance | Foam substrate helps repel fluids |
| Conductive interface | Proprietary conductive adhesive hydrogel |
| Connector | Snap |
| Shape | Teardrop |
| Manufacturer-listed size | 1.44 inches |
| Approximate metric size | 36.6 mm |
| Radiolucent | No |
| Radiolucent counterpart | Kendall 600 Series |
| Additional gel required | No |
| Reusable | No |
| Balego case options | 600 or 1,000 total electrodes |
The four Balego order codes represent packaging variations within the same 200 Series electrode family rather than four different electrode constructions.
Package and case options
| Balego order code | Series model | Electrodes per pouch | Pouches per case | Total electrodes |
|---|---|---|---|---|
| 31050522 | Kendall 200 | 100 | 10 | 1,000 |
| 31078135 | Kendall 230 | 30 | 20 | 600 |
| 31478368 | Kendall 233 | 3 | 200 | 600 |
| 31478376 | Kendall 235 | 5 | 120 | 600 |
Recommended Shopify variant names
Replace abbreviated variant labels with:
- 31050522 / Kendall 200 — 100 per pouch, 10 pouches, 1,000 per case
- 31078135 / Kendall 230 — 30 per pouch, 20 pouches, 600 per case
- 31478368 / Kendall 233 — 3 per pouch, 200 pouches, 600 per case
- 31478376 / Kendall 235 — 5 per pouch, 120 pouches, 600 per case
This makes it clear that “3 per pack” and “5 per pack” describe the individually sealed pouch—not the complete case quantity.
Which package configuration should a facility choose?
| Workflow | Suggested configuration | Why |
|---|---|---|
| Centralized bulk stocking | Kendall 200, 100/pouch | Fewer pouches and the lowest packaging frequency |
| Department or cart stocking | Kendall 230, 30/pouch | Moderate pouch quantity for recurring use |
| Three-lead monitoring kits | Kendall 233, 3/pouch | Pre-grouped three-electrode quantities |
| Five-lead monitoring kits | Kendall 235, 5/pouch | Pre-grouped five-electrode quantities |
| Individual procedure packs | Kendall 233 or 235 | Helps reduce counting and repackaging steps |
| High-volume hospital supply | Kendall 200 | 1,000 electrodes per case |
The electrode itself remains part of the same 200 Series family. The best configuration depends primarily on lead setup, turnover, storage practices, and open-pouch workflow.
Why choose Medi-Trace 200 Series electrodes?
Compact footprint
At approximately 1.44 inches, the 200 Series is smaller than many general-purpose and stress-monitoring foam electrodes. The reduced footprint can be useful when several leads must be positioned on an adult torso or when available placement space is limited.
Fluid-resistant foam backing
The foam substrate helps repel fluids and conforms to ordinary body contours. This makes it practical for routine inpatient and observation workflows where the electrode must remain flat against the skin during general monitoring.
Conductive adhesive hydrogel
The integrated hydrogel provides the adhesive and conductive interface between the patient’s skin and ECG monitoring system. Cardinal Health describes it as supporting adhesion and clear, reliable tracings while avoiding messy residue.
Teardrop profile
The tapered portion of the electrode provides clinicians a defined area to grasp when removing the pad from its liner or lifting it from the patient. Handling the foam edge rather than the gel helps limit contamination of the conductive surface.
Multiple pouch sizes
The same electrode is offered in pouches of 3, 5, 30, or 100. This lets facilities align pouch quantity with their monitoring protocols without changing electrode type.
Where are Medi-Trace 200 electrodes commonly used?
The 200 Series for lower- to mid-acuity settings.
| Clinical area | Typical role |
|---|---|
| General inpatient units | Routine adult ECG monitoring |
| Medical-surgical floors | Standard bedside monitoring |
| Observation units | Shorter-term cardiac observation |
| Outpatient procedure areas | Monitoring when clinically required |
| Preoperative and postoperative areas | Compatible routine monitoring workflows |
| Rehabilitation facilities | Monitoring under facility protocols |
| Long-term care environments | Compatible provider-directed monitoring |
| Home monitoring programs | Only when supplied and directed by the monitoring provider |
These electrodes are not specifically positioned for stress testing, highly active patients, heavy perspiration, neonatal monitoring, or diagnostic resting ECG procedures. Other electrode families may be more appropriate for those applications.
Browse our complete monitoring EKG/ECG electrode collection.
ECG monitoring electrodes are not stimulation pads
The Medi-Trace 200 Series is designed to receive the heart’s electrical signal and transfer it to compatible monitoring equipment.
It is not designed to deliver therapeutic current.
| Electrode category | Primary purpose | Typical connector | Example |
|---|---|---|---|
| ECG monitoring electrode | Records cardiac electrical activity over time | Snap | Medi-Trace 200 |
| Resting diagnostic electrode | Short diagnostic ECG acquisition | Tab or clip | Kendall 5400 or 5500 |
| Stress/Holter electrode | Monitoring with greater movement or perspiration | Snap | Medi-Trace 530 |
| TENS/NMES electrode | Delivers electrical stimulation | Pin, snap, or proprietary | Balego reusable TENS pads |
| Defibrillation electrode | Defibrillation, cardioversion, or pacing | Device-specific cable | Multifunction defibrillation pad |
| Electrosurgical return electrode | Returns electrosurgical current | Device-specific | Grounding or return pad |
Do not use the Medi-Trace 200 Series for TENS, NMES, EMS, FES, iontophoresis, defibrillation, pacing, or electrosurgical return applications.
Customers looking for stimulation pads should visit our Electrotherapy Electrodes collection.
Product comparison
Medi-Trace 200 vs. Medi-Trace 450 vs. Medi-Trace 530
| Feature | Medi-Trace 200 Series | Medi-Trace 450 Series | Medi-Trace 530 Series |
|---|---|---|---|
| Primary positioning | Economical general adult monitoring | Multipurpose housewide adult monitoring | Challenging, active, or diaphoretic monitoring |
| Acuity focus | Lower-to-mid acuity | Broad general-purpose use | Stress, Holter, activity, and higher-demand environments |
| Shape | Small teardrop | Rectangle | Larger teardrop |
| Size | 1.44 in. | 1.438 × 1.656 in. | Approximately 1.75 in. |
| Backing | Foam | Thin foam | Foam |
| Connector | Snap | Snap | Snap |
| Conductive adhesive hydrogel | Yes | Yes | Yes |
| Adhesion positioning | General-purpose | Multipurpose | More aggressive for difficult environments |
| Radiolucent | No | No | No |
| Pouch options at Balego | 3, 5, 30, or 100 | 3, 5, or 50 | 30 |
| Total case quantity | 600 or 1,000 | 600 or 1,000 | 600 |
| Best fit | Compact, cost-conscious routine monitoring | Standardized housewide monitoring | Motion, perspiration, stress, and Holter workflows |
The 200 Series for lower- to mid-acuity floors and the 450 Series for multipurpose adult monitoring. The 530 Series is commonly selected when stronger adhesion is needed for stress testing, Holter monitoring, active patients, or diaphoretic conditions.
Choose the Medi-Trace 200 when:
- A compact adult electrode is preferred.
- Routine lower- or mid-acuity monitoring is the main application.
- Cost-conscious standardization is a priority.
- Pre-grouped 3- or 5-electrode pouches support the workflow.
- The patient is expected to have normal perspiration and movement.
Choose the Medi-Trace 450 when:
- A broader, multipurpose housewide electrode is desired.
- A rectangular pad and larger gel-contact area are preferred.
- A facility wants 3-, 5-, or 50-electrode pouches.
- Standard general monitoring is the primary need.
Choose the Medi-Trace 530 when:
- Patients may move or perspire heavily.
- Stress testing or Holter monitoring is performed.
- More aggressive adhesion is required.
- A larger foam electrode is appropriate.
Medi-Trace 200 vs. Kendall 600 radiolucent electrodes
| Feature | Medi-Trace 200 | Kendall 600 Series |
|---|---|---|
| General design | Compact foam ECG monitoring electrode | Radiolucent version of the compact foam design |
| Connector | Snap | Snap |
| Conductive hydrogel | Yes | Yes |
| Radiolucent | No | Yes |
| Imaging workflow | Follow imaging protocol; removal may be required | Designed for workflows requiring radiolucency |
| Best fit | Routine monitoring without a radiolucency requirement | Monitoring when imaging compatibility is required |
The Kendall 600 Series is the radiolucent version of the 200 Series.
Do not assume that a non-radiolucent electrode may remain on a patient during imaging. Follow the imaging department’s protocol and the equipment manufacturer’s instructions.
Medi-Trace 200 vs. resting diagnostic tab electrodes
| Feature | Medi-Trace 200 | Kendall 5400 Resting Tabs | Balego 5500 Diagnostic Tabs |
|---|---|---|---|
| Purpose | Ongoing monitoring | Resting diagnostic ECG | Resting diagnostic ECG |
| Connector | Snap | Tab/grabber | Tab/grabber |
| Backing | Foam | Vinyl diagnostic tab | Radiolucent diagnostic tab |
| Wear time | Monitoring workflow | Short diagnostic recording | Short diagnostic recording |
| Adult use | Yes | Yes | Yes |
| Pediatric positioning | Not the primary 200 Series positioning | Cardinal lists 5400 for adult and pediatric use | Follow product-specific instructions |
| Reusable | No | No | No |
| Best fit | Bedside or ambulatory monitoring | Standard resting ECG acquisition | High-volume radiolucent resting ECG |
The 400 and 5500 products are diagnostic tab electrodes for resting ECG applications, which are different from continuous or repeated monitoring with the 200 Series.
How to apply Medi-Trace 200 ECG electrodes
Follow the ECG monitor instructions and the facility’s skin-preparation and lead-placement procedures.
1. Confirm the correct electrode
Before opening the pouch, verify:
- Correct order code and pouch quantity
- Adult monitoring application
- Snap-lead compatibility
- Non-radiolucent construction is acceptable
- The package is within its expiration date
- Pouch is sealed and undamaged
2. Prepare the skin
Select the sites required by the monitoring protocol. The skin should generally be:
- Clean
- Dry
- Intact
- Free of lotion and body oil
- Free of excessive perspiration
- Prepared according to facility policy
Excessive hair may need to be clipped—not shaved—when facility procedures require improved electrode contact.
3. Connect the monitoring lead
The lead may be snapped to the electrode before or after application, depending on the facility’s workflow. Confirm that the snap is fully engaged.
Avoid twisting the snap after the pad has been applied, as this action can place unnecessary tension on the foam and skin.
4. Remove the pad from its liner
Hold the electrode by the foam edge or tapered portion. Avoid touching the conductive hydrogel.
5. Apply it evenly
Place the electrode at the selected monitoring site and press from the center outward.
Make sure there are no
- Folded edges
- Air gaps
- Contaminated gel areas
- Lifted sections
- Lead wires pulling against the pad
6. Confirm signal quality
Check for an appropriate tracing and absence of a lead-off warning.
When signal quality is poor, inspect:
- Skin preparation
- Pad adhesion
- Snap engagement
- Lead-wire condition
- Electrode position
- Patient movement
- Electrode age or dryness
7. Remove and discard
Disconnect the lead according to the monitor instructions. Lift the foam edge and peel the electrode back slowly.
Dispose of the used electrode according to facility policy. Do not reapply it to the same patient or use it on another patient.
Storage and pouch handling
- Store unopened cases according to the temperature and humidity directions printed on the current package.
- Keep pouches away from excessive heat, moisture, and direct sunlight.
- Retain unused electrodes in their original pouch.
- Close the pouch promptly after removing the needed quantity.
- Do not use an electrode that is dry, contaminated, damaged, or expired.
- Do not place a removed or used electrode back into the pouch.
- Follow the current label for open-pouch storage life rather than relying on a generalized electrode rule.
The Medi-Trace 200 hydrogel can remain fresh for up to 45 days after pouch opening, but the current package directions should control storage and disposal decisions.
Troubleshooting guide
| Problem | Possible cause | Recommended action |
|---|---|---|
| Lead-off warning | Snap is not fully connected | Reconnect the lead securely |
| The lead-off warning continues | The electrode is lifting or dry | Prepare the skin and apply a fresh electrode |
| Noisy ECG tracing | Patient movement | Reduce movement when clinically possible |
| Noisy tracing | Poor skin contact | Reprepare the site and replace the pad |
| Intermittent signal | Damaged or loose lead wire | Inspect or replace the lead according to protocol |
| The pad will not adhere | Lotion, oil, sweat, or hair | Select and prepare a new site |
| One edge lifts | Body contour or lead-wire tension | Reroute the wire and use a fresh electrode |
| The gel looks dry | Pouch storage or age issue | Discard the electrode |
| Skin becomes irritated | Adhesive sensitivity, moisture, or prolonged contact | Remove and assess according to clinical policy |
| An electrode appears on an image | The product is non-radioluscent. | Follow imaging protocol or use a radiolucent electrode |
| Tracing remains poor with fresh pads | Monitor, cable, placement, or patient issue | Follow the monitor manufacturer’s troubleshooting process |
| The snap detaches during movement | Lead tension or incomplete snap engagement | Reconnect and support the lead wire |
| Several electrodes fail from one pouch | The pouch may have been improperly stored | Quarantine the pouch and inspect lot and expiration information |
Additional Recommended Resources
Reviews
Rating Snapshot
No reviews yet — be the first to share your thoughts.
FAQs
What are Kendall Medi-Trace 200 Series electrodes?
They are disposable adult foam ECG/EKG monitoring electrodes designed for routine lower- to mid-acuity cardiac monitoring. The family includes models 200, 230, 233, and 235, which differ primarily by pouch and case quantity.
What size are they?
The 200 Series is 1.44 inches, approximately 36.6 mm. The teardrop profile is compact for convenient lead placement.
What connector do they use?
They use a standard snap connection for compatible ECG monitoring lead wires.
Are the four models different sizes?
Cardinal Health groups all four order codes under the 200 Series construction. Their primary difference is package configuration:
- 200: 100 per pouch
- 230: 30 per pouch
- 233: 3 per pouch
- 235: 5 per pouch
How many electrodes are in a case?
Depending on the selected order code, the case contains either 600 or 1,000 electrodes.
Are these adult or pediatric electrodes?
The 200 Series as a general adult monitoring electrode. Select a pediatric or neonatal product when required by the patient and monitoring protocol.
Are they radiolucent?
No. The Kendall 200 Series is non-radiolucent. Cardinal Health identifies the Kendall 600 Series as the radiolucent counterpart.
Are they appropriate for stress testing?
They are positioned for routine lower- to mid-acuity monitoring. The Medi-Trace 530 is more specifically positioned for stress, Holter, active, and diaphoretic applications.
Can they be used for a resting 12-lead ECG?
They are snap-style monitoring electrodes. Resting ECG systems commonly use tab-style diagnostic electrodes such as the Kendall 5400 or Balego 5500. Use the electrode style specified by the ECG equipment and facility protocol.
Can Medi-Trace 200 electrodes be reused?
No. They are disposable monitoring electrodes. Remove and discard them according to facility procedures.
Do they need separate conductive gel?
No. Conductive adhesive hydrogel is incorporated into the electrode. Additional gel is not normally used.
Can they be used for TENS or NMES?
No. TENS and NMES pads deliver therapeutic stimulation current. Medi-Trace 200 electrodes are designed to acquire cardiac signals for ECG monitoring.
Browse compatible stimulation products in our Electrotherapy Electrodes collection.
Can they be used for defibrillation or pacing?
No. They are routine ECG monitoring electrodes, not multifunction defibrillation or pacing pads.
Are they hypoallergenic?
Cardinal Health does not describe the 200 Series as hypoallergenic on its current product page. Avoid that claim unless product-specific documentation is available.
Why does the product have a teardrop shape?
The tapered section provides a convenient area for handling and removal while maintaining a compact conductive contact area. Cardinal Health specifically identifies the shape as facilitating removal from both the liner and the patient.
Why choose a three- or five-electrode pouch?
Small pouches can align with common three- or five-lead monitoring setups, reduce counting, and keep unused electrodes sealed until another patient or procedure.
Why choose the 100-electrode pouch?
It may be more efficient for high-volume departments with centralized stocking and frequent electrode use.