Richmar Quattro 2.5 DQ8450 professional 4-channel electrotherapy device

Richmar

Richmar Quattro 2.5 DQ8450 | 4-Channel TENS, EMS, IFC & Russian Stim

Ref: RICHMAR-QUATTRO-2-5

Category: Electrotherapy Device

SKU: DQ8450

GTIN/UPC: 092237611623

$649.95
$699.99
5% OFF, Buy 2+

In stock

🛡 Authorized Dealer - Authentic Products & Manufacturer Warranty

💲Price Match Guarantee

🚚 FREE & FAST Shipping

◆ Easy, Secure Checkout

💬Questions? Contact Our Product Specialists

Richmar® Quattro™ 2.5 Professional 4-Channel Electrotherapy Device

The Richmar Quattro 2.5 is a professional four-channel electrical-stimulation system for physical therapy clinics, rehabilitation departments, chiropractic offices, sports-medicine practices, athletic-training rooms, and other clinician-directed treatment settings.

Five electrotherapy waveform families are built into one compact tabletop device:

  • TENS
  • EMS
  • Russian stimulation
  • IF-2P premodulated interferential
  • IF-4P traditional interferential

The Quattro 2.5 also provides two programmable treatment groups, 50 preset programs, user-defined protocols, professional two-step programming, constant-current and constant-voltage operation, and a large graphical LCD display. This combination gives clinicians considerably more control than a basic portable TENS or two-channel combination stimulator.

Sale by or on the order of a physician or licensed practitioner. It is intended for use under the continuing supervision of a qualified professional.

For complete setup, parameter, safety, cleaning, error code, and troubleshooting information, read our Quattro 2.5 Manual Summary, Safety, and Specifications.

Product highlights

  • Professional microprocessor-controlled electrotherapy system
  • Four stimulation output channels
  • Two independently programmable channel groups
  • Individual output-intensity control for all four channels
  • TENS, EMS, Russian, IF-2P, and IF-4P waveform families
  • Synchronous and asynchronous EMS modes
  • Synchronous and asynchronous Russian modes
  • Two programmable treatment timers
  • Ten presets per waveform family
  • Fifty total presets
  • User-defined protocol storage
  • Professional mode with two treatment steps
  • Constant-current and constant-voltage output choices
  • Interferential vector and frequency-modulation controls
  • Large graphical LCD display
  • Physical knobs for direct channel-intensity adjustment
  • Maximum treatment time of 60 minutes
  • AC-powered tabletop and therapy-cart design
  • Starter self-adhesive and reusable rubber electrodes
  • Two-year manufacturer warranty

The device is suitable for tabletop, therapy cart, or mobile use, but the device requires its supplied AC power adapter rather than operating from an internal battery.

Quick product specifications

SpecificationQuattro 2.5 detail
ManufacturerRichmar
ModelDQ8450
Device typeProfessional clinical electrotherapy system
Output channels4
Programmable channel groupsChannels 1–2 and Channels 3–4
Intensity controlsSeparate control for each channel
Treatment timers2
Waveform familiesTENS, EMS, Russian, IF-2P, and IF-4P
Selectable display modesIF-4P, IF-2P, TENS, EMS synchronous, EMS asynchronous, Russian synchronous and Russian asynchronous
Preset programs10 per waveform family; 50 total
Custom programmingYes
Professional modeTwo treatment steps within a program
Output regulationConstant current or constant voltage
Maximum treatment time60 minutes
Power-adapter input100–240 VAC, 50–60 Hz
Adapter output15 V, 1.2 A maximum
Battery operationNo
Device dimensions9.8" L × 7.3" W × 3.25" H
Device protectionClass II equipment
Warranty2 years
U.S. sale statusPrescription device

Understanding the four-channel design

The Quattro 2.5 has four output channels, but the programming is organized into two treatment groups.

Treatment groupChannelsShared programmingIndividual adjustment
Group 1Channels 1 and 2Waveform, program, timer and treatment parametersSeparate intensity for Channels 1 and 2
Group 2Channels 3 and 4Waveform, program, timer and treatment parametersSeparate intensity for Channels 3 and 4

This arrangement allows the clinician to run a different waveform, program, timer, and intensity configuration on Channels 1–2 than on Channels 3–4. This can support two treatment areas or two patients at the same time when clinically appropriate and properly supervised.

It should not be marketed as four entirely separate programmable systems. The intensities are individually controlled, but waveform and timing selections are shared within each two-channel group.

Electrotherapy modes explained

ModeElectrode arrangementGeneral purpose under professional direction
TENSCommonly 2 or 4 electrodesSensory-level stimulation for symptomatic pain relief
EMS synchronousTwo channels contract togetherCoordinated muscle-contraction programs
EMS asynchronousChannels alternateAlternating muscle or bilateral stimulation programs
Russian synchronousChannels burst togetherMedium-frequency muscle-contraction programs
Russian asynchronousChannels alternateAlternating Russian-stimulation programs
IF-2P / Premodulated2 electrodesPremixed interferential-style output for focused or simpler placement
IF-4P / Interferential4 electrodesTraditional crossed-current interferential arrangement

Symptomatic relief of chronic intractable pain and acute post-traumatic or post-surgical pain for TENS and interferential modes. Its EMS and Russian indications include muscle-spasm relaxation, prevention of disuse atrophy, local circulation, muscle re-education, maintaining or increasing range of motion, and immediate postoperative lower-leg stimulation for prevention of venous thrombosis when appropriately ordered and supervised.

For a broader explanation of sensory and muscle-stimulation modalities, read TENS vs. NMES: Differences, Uses, and Safety.

IF-2P vs. IF-4P interferential stimulation

FeatureIF-2P / PremodulatedIF-4P / Traditional IFC
Electrodes normally used24
Current formationInterference is produced inside the deviceTwo medium-frequency currents intersect in the tissue
Setup complexitySimplerMore placement-dependent
Treatment footprintOften used for smaller or more focused areasOften used for broader crossed-current coverage
Carrier frequency4 kHz4 kHz
Beat-frequency controlsAdjustable low and high beat settingsAdjustable low and high beat settings
Vector controlNot required in the same mannerAutomatic or manual vector settings available

The Quattro 2.5 allows a static beat frequency or frequency-modulated sweep. IF-4P additionally includes automatic vector control from 0% to 100% and manual vector adjustment from 0° to 90°.

Explore related products and education in our Interferential Therapy collection.

Technical waveform ranges

WaveformKey adjustable ranges
IF-4P4 kHz carrier; 1–150 Hz beat-frequency range; vector control; 0–50 mA CC or 0–50 V CV at 1 kΩ
IF-2P4 kHz carrier; 1–150 Hz beat-frequency range; 0–50 mA CC or 0–50 V CV at 1 kΩ
TENS1–250 Hz; 30–400 µs phase duration; frequency modulation; burst; amplitude modulation; 0–100 mA CC or 0–100 V CV at 1 kΩ
EMS1–250 Hz; 30–400 µs pulse duration; amplitude and frequency modulation; contraction/relaxation cycles; ramp controls; 0–100 mA CC or 0–100 V CV at 1 kΩ
Russian2.5 kHz carrier; 2–100 Hz burst frequency; 10%–50% duty cycle; ramp and cycle controls; 0–50 mA CC or 0–50 V CV at 1 kΩ
Treatment time1–60 minutes

These are device capabilities, not recommended patient settings. Treatment parameters must be selected according to the prescription, clinical assessment, waveform, electrode size, placement, patient response, and complete device instructions.

Constant current vs. constant voltage

The Quattro 2.5 allows the clinician to select either CC or CV operation.

Output modeHow it behavesPractical consideration
Constant currentThe unit adjusts voltage within its capability to maintain the selected current as resistance changesCommonly selected when controlled current delivery is important
Constant voltageThe unit maintains the selected voltage; delivered current changes as circuit resistance changesMay be selected according to the electrode system, waveform and clinical protocol

Neither mode is automatically superior for every treatment. The choice should be made by a trained clinician using the manual, electrode instructions, facility protocol, and patient-specific treatment plan.

What comes with the Quattro 2.5?

Richmar’s manual lists the following starter accessories:

Included itemManual-listed quantity
Quattro 2.5 DQ8450 device1
2" × 2" self-adhesive electrodes8
2" × 3.5" self-adhesive electrodes8
2.5" × 3.5" rubber electrodes4
2.75" × 4.3" rubber electrodes4
2.75" × 4" electrode sponges4
3" × 4.75" electrode sponges4
3" × 23.5" elastic straps2
3" × 47" elastic straps2
Lead wires4
AC power adapter1
Cable-connector assemblies2 in the manual
Instruction manual1
Includes the Quattro 2.5 device, starter self-adhesive electrodes, rubber electrodes, sponges, elastic straps, lead wires, device connectors, power supply, and instruction manual. Accessory quantities and part numbers are subject to the current Richmar package configuration.

Electrode options and replacement supplies

The Quattro 2.5 can be used with compatible self-adhering electrodes or reusable rubber electrodes with properly prepared sponges or approved conductive gel.

AccessoryBest fitBalego link
Reusable self-adhesive electrodesRoutine TENS, EMS, Russian and IFC setupsBalego TENS/NMES/FES Electrodes
Clinic replacement electrodesBulk clinical electrode supplyDURA-STICK PLUS Electrodes
Complete electrode selectionCompare brands, sizes and shapesElectrotherapy Electrodes
Conductive gel for compatible rubber electrodesLong-duration, salt-free conductive contactSpectra 360 Electrode Gel
Saline conductive gelCompatible procedures when the equipment directions specify saline gelSignaGel Electrode Gel

Use self-adhesive electrodes with at least 25 cm² of active surface area and specifically recommends a minimum size of approximately 2" × 2". Electrodes should be fully adhered, separated from one another, and selected to fit the anatomy and planned current density.

Added conductive gel is normally not needed with pre-gelled self-adhesive pads. Gel or properly moistened sponges are used with the reusable rubber-electrode system as directed in the manual.

Quattro 2.5 vs. other electrotherapy devices

FeatureQuattro 2.5Richmar ComboCareTheraTouch EX4Four Channel Stim DS5402InTENSity Select Combo II
FormatProfessional tabletopProfessional tabletop combination unitAdvanced touchscreen clinical unitPortable handheldRechargeable handheld
Stimulation channels4, arranged in two groups24 independent channels4 isolated channels2 isolated channels
TENSYesYesYesYesYes
EMS/NMESYesYesYesYesYes
RussianYesYesYesYesYes
Premodulated / IF-2PYesYesYesIF modeIF mode
Traditional IF-4PYesYesYesYesDevice-specific IF mode
UltrasoundNo1 and 3 MHzNoNoNo
Additional advanced waveformsNoNoHigh volt, microcurrent, RAAS, and othersNoNo
InterfaceLCD, knobs and parameter buttonsClinical control panelBilingual touchscreenPortable button interfaceCompact digital interface
Presets50 plus custom programsPresets and custom controlClinical protocols plus up to 99 custom protocolsDevice programsBody-part presets and custom programs
PowerAC adapterAC powerAC powerAA batteries or AC adapterRechargeable battery
Best fitClinics wanting capable four-channel electrotherapy without ultrasoundClinics wanting e-stim plus therapeutic ultrasoundClinics wanting a premium touchscreen and broader waveform libraryPortable four-channel use at a lower priceCompact two-channel clinic-to-home programs

Choose the Quattro 2.5 when:

  • Four-channel clinical stimulation is needed.
  • Both premodulated and traditional four-pole IFC are important.
  • The clinic wants TENS, EMS, and Russian stimulation in the same system.
  • Two treatment groups with separate timers are useful.
  • Fifty presets and custom programming provide enough flexibility.
  • Ultrasound is not required.
  • A conventional clinical LCD-and-dial interface is preferred.
  • The clinic wants a lower-cost option than a premium touchscreen system.

Appropriate professional settings

SettingHow the Quattro 2.5 may fit
Physical therapy clinicConsolidates sensory, motor and interferential waveforms in one system
Chiropractic officeProvides TENS, premodulated and traditional IFC options
Rehabilitation departmentSupports repeatable preset and custom treatment workflows
Sports medicine practiceOffers pain-focused and clinician-directed muscle-stimulation programs
Athletic-training roomFour channels allow broader or bilateral electrode configurations
Therapy cartThe compact AC-powered design can be moved between treatment areas
Multi-provider clinicDual channel groups can support two distinct treatment configurations under direct supervision

The device is not a general consumer home TENS unit. Its parameter range, output capability, professional programming, electrode requirements, and clinical warnings make clinician supervision essential.

Basic setup overview

This section should remain concise on the product page, with the complete procedure kept in the manual article.

  1. Inspect the device, cables, lead wires, electrodes, and skin.
  2. Connect the AC adapter and switch on the device.
  3. Connect the lead wires through the appropriate Quattro cable connectors.
  4. Place correctly sized electrodes on clean, dry, intact skin.
  5. Select Channels 1–2 or Channels 3–4.
  6. Select the waveform and preset or custom program.
  7. Select constant-current or constant-voltage operation.
  8. Adjust the waveform-specific treatment parameters.
  9. Set the treatment time.
  10. Increase each channel intensity gradually while monitoring the patient.
  11. Reduce output to zero and stop the selected channel group before removing electrodes.

The device performs an initial self-test and includes load detection that can alarm and reset the intensity if adequate electrode contact is not detected.

Important safety information

Safety topicManual-based guidance
Prescription statusUse only under continued supervision of a physician or licensed practitioner
Implanted devicesDo not use on patients with pacemakers, implanted defibrillators or other implanted electronic or metallic devices
Undiagnosed painDo not use for undiagnosed pain syndromes
Anterior neckDo not apply over the front of the neck
Across the chestDo not place current paths across the chest
Head and eyesDo not apply across the head, directly over the eyes or inside body cavities
Skin conditionUse on normal, clean, dry, intact skin
Thrombus historyDo not stimulate over or adjacent to a known thrombus; follow the full manual warning
Electronic monitoringStimulation may interfere with ECG or other monitoring equipment
MRIRemove the device before MRI exposure
Water and sleepDo not use while bathing, showering or sleeping
Driving or machineryDo not use during activities where unexpected contraction or sensation could cause injury
Patient attendancePatients should not be left unattended during treatment
Electrode contactKeep electrodes separated and fully attached

Additional Recommended Resources

Reviews

Rating Snapshot

5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Stars
0

Overall Rating

—

0 Reviews

Review this Product

Sign in to write a review.

No reviews yet — be the first to share your thoughts.

FAQs

What is the Richmar Quattro 2.5?

It is a professional four-channel electrotherapy system offering TENS, EMS, Russian, two-pole premodulated interferential, and four-pole traditional interferential stimulation.

Is the Quattro 2.5 a prescription device?

Yes. Its sale to or on the order of a physician or licensed practitioner.

Does it have four independent channels?

It has four separately adjustable output intensities. Programming is organized into two independent groups: Channels 1–2 and Channels 3–4.

Can it run two different treatments at once?

Yes. The two channel groups can use different waveforms, programs, timers, and intensities. This can support two treatment areas or two patients when appropriately supervised.

How many presets are included?

The device provides 10 presets for each of five waveform families, for a total of 50 presets, plus professional and user-defined programming.

Does it have true four-pole interferential stimulation?

Yes. IF-4P uses four electrodes and a 4 kHz carrier. The device also includes IF-2P premodulated stimulation.

Does it include Russian stimulation?

Yes. It provides synchronous and asynchronous Russian modes using a 2.5 kHz carrier and an adjustable burst frequency from 2 to 100 Hz.

Does it provide NMES?

The device labels its muscle-stimulation waveform as EMS. Its motor-level indications and programmable contraction, relaxation, and ramp functions align with professional neuromuscular electrical-stimulation workflows.

Is it battery-powered?

No. It operates from the included 100–240 VAC power adapter. “Portable” refers to its ability to be carried or moved on a therapy cart, not cordless operation.

Does it include ultrasound?

No. Clinics needing electrical stimulation plus therapeutic ultrasound should compare the Richmar ComboCare.

What electrodes should be used?

Use compatible electrodes that satisfy the device manual’s size, connector, and current-density requirements. The manual recommends self-adhesive electrodes with at least 25 cm² of active area.

Can 1.25-inch or 1.5-inch pads be used?

They fall below the manual’s 25 cm² minimum active-area warning and should not be represented as standard replacement pads for this device. Use approximately 2-inch square or larger electrodes unless Richmar or an appropriately qualified clinician directs otherwise.

Can the included rubber electrodes be used without sponges?

The manual allows either properly moistened sponges or an approved conductive transmission gel. The electrodes must be secured using the appropriate straps.

Can pre-gelled adhesive pads be used with additional gel?

Normally no. Additional gel may interfere with their adhesion. Separate conductive media are primarily used with compatible non-gelled rubber or carbon electrodes.

What is professional mode?

Professional mode allows two programmed treatment steps within one session so selected parameters can change from the first step to the second. (Balego)

What is the maximum treatment time?

The timer can be set from 1 to 60 minutes.

What is the warranty?

A two-year warranty, subject to the warranty terms and exclusions.

Ask your Question