
Cardinal Health Protexis™ Neoprene Surgical Gloves — Sterile, Powder-Free, 50 Pairs/Box
In stock
🛡 Authorized Dealer - Authentic Products & Manufacturer Warranty
💲Price Match Guarantee
🚚 FREE & FAST Shipping
◆ Easy, Secure Checkout
💬Questions? Contact Our Product Specialists
Cardinal Health Protexis™ Neoprene Sterile Surgical Gloves
Cardinal Health Protexis™ Neoprene Surgical Gloves are sterile, powder-free surgical gloves made from synthetic neoprene with a nitrile coating. They provide a non-natural-rubber alternative for operating rooms, ambulatory surgery centers, dental surgical settings, and other sterile procedural environments where natural rubber latex surgical gloves are not appropriate.
Protexis Neoprene gloves are engineered with a thin, soft glove film for tactile response; a hand-specific anatomical shape; an independent thumb design; and an interlocking beaded cuff that helps reduce cuff roll-down during procedures. Each dispenser box contains 50 individually packaged sterile pairs.
Choose your available size above or browse additional medical gloves available from Balego.
Product Highlights
- Sterile surgical gloves
- Synthetic neoprene construction
- Not made with natural rubber latex
- Powder-free formulation
- Nitrile coating
- Hand-specific right-and-left glove design
- Anatomical fit with independent thumb
- Thin design for tactile response
- Interlocking beaded cuff to help resist roll-down
- Approximately 12 inches long
- 0.65 acceptable quality limit for freedom from holes
- Tested for chemotherapy-agent permeation
- 50 sterile pairs per dispenser box
- Cardinal Health Protexis surgical-glove line
Cardinal Health describes the current Protexis neoprene design as softer and thinner than its earlier neoprene surgical gloves while maintaining the applicable physical-property performance.
Protexis Neoprene Specifications
| Specification | Product Detail |
|---|---|
| Manufacturer | Cardinal Health |
| Brand | Protexis™ |
| Product type | Surgical glove |
| Material | Synthetic neoprene, also called polychloroprene |
| Coating | Nitrile coating |
| Sterility | Sterile |
| Packaging | Sterile pairs |
| Powder | Powder-free |
| Natural rubber latex | Not made with natural rubber latex |
| Hand orientation | Hand-specific right and left gloves |
| Color | Ivory or cream |
| Exterior | Smooth with antislip handling characteristics |
| Cuff | Interlocking beaded cuff |
| Length | Approximately 12 in. / 305 mm |
| Finger thickness | Approximately 6.7 mil / 0.17 mm |
| Palm thickness | At least 5.5 mil / 0.14 mm |
| Cuff thickness | At least 5.5 mil / 0.14 mm |
| Tensile strength before aging | At least 17 MPa |
| Ultimate elongation before aging | At least 650% |
| Cuff puncture resistance | At least 5 N |
| Freedom from holes | 0.65 AQL |
| Chemotherapy testing | Tested in accordance with ASTM D6978 |
| Box quantity | 50 pairs |
| Manufacturer case quantity | 4 boxes / 200 pairs |
| Reuse | Single-use product |
A powder-residue limit below 2 mg per glove and testing to applicable ASTM requirements for dimensions, physical properties, freedom from holes, and chemotherapy-agent permeation.
Available Balego Sizes and Model Numbers
| Surgical Glove Size | Cardinal Health Model | Quantity |
|---|---|---|
| 5.5 | 2D73DP55 | 50 pairs per box |
| 6.5 | 2D73DP65 | 50 pairs per box |
| 8.0 | 2D73DP80 | 50 pairs per box |
Select the same surgical-glove size normally used by the clinician. Surgical gloves should fit closely without restricting finger movement, placing excessive tension across the palm, or leaving loose material at the fingertips.
The broader manufacturer line includes additional half and whole sizes, but the options displayed above reflect the sizes currently offered on this Balego product page.
Why Choose Synthetic Neoprene Surgical Gloves?
Synthetic neoprene is a man-made elastomer that provides an alternative when a natural-rubber surgical glove is not desired. It should not be confused with nitrile exam glove material: Protexis Neoprene is principally a neoprene surgical glove with a nitrile coating.
| Neoprene Glove Feature | Practical Benefit |
|---|---|
| No natural rubber latex used as glove material | Provides an option for facilities seeking to avoid natural-rubber surgical gloves |
| Thin glove film | Supports tactile feedback during instrument handling |
| Elastic synthetic construction | Allows the glove to move with the hand |
| Nitrile coating | Helps support donning and glove performance |
| Anatomical hand mold | Reduces excess material compared with an ambidextrous exam glove |
| Independent thumb design | Supports more natural movement of the thumb, fingers, and palm |
| Beaded locking cuff | Helps reduce cuff roll-down |
| Sterile paired packaging | Supports aseptic donning for surgical procedures |
| Powder-free design | Avoids glove powder within the sterile field |
Protexis’s proprietary glove mold incorporates an independent thumb to support anatomical fit and natural movement.
Anatomical, Hand-Specific Fit
Unlike most ambidextrous examination gloves, Protexis Neoprene Surgical Gloves are formed specifically for the right and left hands.
This design can help provide:
- Closer fingertip fit
- Less unused material in the palm
- More natural thumb positioning
- Improved instrument control
- Reduced resistance during finger movement
- Better fit during longer sterile procedures
Correct sizing remains essential. A glove that is too small can place excessive tension on the glove film and increase hand fatigue. A glove that is too large may reduce tactile control and leave loose material around the fingertips.
Tactile Response and Glove Thickness
Protexis neoprene gloves have a target fingertip thickness of approximately 6.7 mils, with palm and cuff thicknesses of at least 5.5 mils. Cardinal Health positions this relatively thin construction as a way to support tactile response while maintaining the glove’s required physical properties.
A thinner glove is not automatically the correct glove for every procedure. Glove selection should consider the following:
- Procedure type
- Expected exposure
- Instrumentation
- Duration
- Puncture risk
- Chemical or medication exposure
- Single- or double-gloving protocol
- Clinician fit and tactile preference
Freedom from Holes: What Does 0.65 AQL Mean?
AQL means acceptable quality limit. For surgical gloves, it is used in sampling inspections for freedom from holes. A lower AQL represents a stricter quality threshold.
Protexis Neoprene Surgical Gloves have a manufacturer-reported freedom-from-holes level of 0.65 AQL, compared with an industry benchmark of 1.5 cited in Cardinal Health’s product literature.
AQL does not mean that a glove cannot be damaged after opening. Always inspect the sterile package and glove before use, and replace a glove immediately when a puncture, tear, or loss of barrier integrity is suspected.
Chemotherapy-Agent Permeation Testing
Protexis Neoprene Surgical Gloves have been tested for chemotherapy-agent permeation in accordance with ASTM D6978. This testing does not mean that the gloves are suitable for every chemotherapy medication or every exposure duration.
Important Carmustine Warning
Do not use Protexis Neoprene Surgical Gloves with carmustine, also called BCNU, at a concentration of 3.3 mg/mL. Cardinal Health reports an average breakthrough-detection time of approximately 31.1 minutes under the cited test conditions.
When chemotherapy medications are present:
- Identify every medication and concentration in use.
- Review the current Cardinal Health permeation data.
- Review the drug labeling and safety data sheet.
- Follow the healthcare facility’s hazardous-drug policy.
- Observe required glove-change intervals.
- Use double gloving when required by policy or procedure.
- Replace gloves immediately after contamination, puncture, or suspected loss of integrity.
“Chemo tested” should not be interpreted as universal protection against all antineoplastic medications, concentrations, combinations, or exposure periods.
Protexis Neoprene vs. Protexis Polyisoprene Surgical Gloves
Both neoprene and synthetic polyisoprene provide surgical-glove options that are not made with natural rubber latex, but the materials have different handling characteristics.
| Feature | Protexis Neoprene | Protexis PI |
|---|---|---|
| Primary material | Synthetic neoprene | Synthetic polyisoprene |
| Natural rubber latex | Not used as glove material | Not used as glove material |
| Sterile | Yes | Yes |
| Powder-free | Yes | Yes |
| Target finger thickness | About 6.7 mil / 0.17 mm | About 9.1 mil / 0.23 mm |
| Reported freedom from holes | 0.65 AQL | 0.65 AQL |
| General positioning | Thin synthetic neoprene option | Multipurpose synthetic polyisoprene option |
| Fit | Anatomical, hand-specific | Anatomical, hand-specific |
| Cuff | Beaded cuff | Beaded cuff |
| Main selection factor | Neoprene material preference and thin construction | Polyisoprene feel and material preference |
Protexis PI is not simply a thicker version of the neoprene glove; it uses a different synthetic material. Clinicians and supply managers should evaluate fit, tactility, exposure requirements, procedure type, and cost before standardizing a surgical glove.
Neoprene Surgical Gloves vs. Nitrile Exam Gloves
| Feature | Protexis Neoprene Surgical Gloves | Typical Nitrile Exam Gloves |
|---|---|---|
| Intended role | Sterile surgical procedures | Patient examinations and general clinical tasks |
| Sterility | Sterile | Usually nonsterile |
| Packaging | Individually packaged pairs | Loose gloves in a dispenser box |
| Hand design | Separate right and left gloves | Usually ambidextrous |
| Sizing | Surgical half and whole sizes | Usually small through extra-large |
| Length | Approximately 12 inches | Commonly around 9.5 inches |
| Primary material | Synthetic neoprene | Nitrile |
| Powder-free | Yes | Commonly |
| Aseptic surgical use | Designed for this role | Standard nonsterile exam gloves are unsuitable |
| Cost per glove | Higher | Lower |
A nonsterile nitrile examination glove should not be substituted when a sterile surgical glove is required.
Protexis Neoprene vs. Natural Rubber Latex Surgical Gloves
| Purchasing Factor | Protexis Neoprene | Natural Rubber Latex Surgical Glove |
|---|---|---|
| Primary material | Synthetic neoprene | Natural rubber latex |
| Natural latex proteins | Natural rubber latex is not used as glove material | Present |
| Powder | Powder-free | It depends on product; powdered medical gloves are no longer marketed in the United States |
| Elasticity and feel | Synthetic-neoprene characteristics | Traditional natural-rubber feel |
| Sterile surgical option | Yes | Yes |
| Best fit | Facilities or users seeking a synthetic neoprene surgical glove | Users and procedures where natural-rubber latex is permitted |
| Allergy considerations | Avoids natural-rubber glove material but may contain other sensitizing chemicals | Natural-rubber latex proteins can cause allergic reactions |
“Not made with natural rubber latex” does not mean “hypoallergenic.” Users can react to glove ingredients other than natural-rubber proteins. Review the package labeling and facility allergy protocols before use.
Common Clinical Settings
Protexis Neoprene Surgical Gloves may be considered for appropriate sterile procedures in the following:
- Hospital operating rooms
- Ambulatory surgery centers
- Outpatient procedural facilities
- Dental and oral-surgery practices
- Podiatric surgery
- Veterinary surgical settings
- Labor and delivery departments
- Specialty procedural suites
- Clinical environments seeking a synthetic neoprene glove option
The clinician and healthcare facility remain responsible for determining whether the glove’s material, thickness, testing, and barrier characteristics are appropriate for a particular procedure.
Facilities can also browse Balego’s skin and wound-management supplies and sharps disposal containers.
Donning Guidance
Follow the facility’s approved sterile-gloving procedure.
- Confirm the correct glove size.
- Inspect the outer package for damage, moisture, or an expired use date.
- Verify that the sterile package is intact.
- Perform surgical hand preparation according to facility protocol.
- Open the package without contaminating its contents.
- Identify the right and left glove.
- Don using the facility’s closed- or open-gloving technique.
- Confirm that the cuff is properly positioned over the gown cuff when applicable.
- Inspect both gloves for tears, punctures, or defects.
- Replace any glove with suspected loss of integrity.
Glove Changing and Disposal
Replace the gloves:
- After a puncture or tear
- After suspected barrier failure
- After contamination
- When required by the procedure
- At the glove-change interval established by facility policy
- When required by hazardous-drug handling protocols
- Before moving from a contaminated task to a clean task
Protexis Neoprene Surgical Gloves are single-use medical products. Do not wash, disinfect, resterilize, or reuse them. Dispose of used gloves according to facility policy and applicable medical-waste requirements.
Storage
Store unopened gloves:
- In a clean, dry location
- At the temperature specified on the package
- Away from direct sunlight
- Away from excessive heat and humidity
- Away from ozone-generating equipment
- Away from chemicals that could damage the glove material
- In the original packaging until needed
Rotate inventory by expiration date and inspect packages before placing them into procedural supply areas.
Packaging Information
| Ordering Level | Quantity |
|---|---|
| Sterile package | 1 pair |
| Dispenser box | 50 pairs |
| Manufacturer case | 4 boxes |
| Total manufacturer case quantity | 200 pairs |
Who Should Choose Protexis Neoprene Surgical Gloves?
These gloves may be a suitable choice when a facility needs the following:
- A sterile surgical glove
- A synthetic neoprene glove
- A product not made with natural rubber latex
- Powder-free construction
- A thin glove designed for tactile response
- Hand-specific anatomical sizing
- A secure beaded cuff
- 0.65 AQL freedom-from-holes testing
- Chemotherapy-agent permeation data
- Sterile paired packaging
- A Cardinal Health surgical-glove product
Ordering Protexis Neoprene Surgical Gloves
Select the required surgical-glove size before adding the box to your cart. Each box contains 50 sterile pairs.
For related clinical supplies, explore:
Protexis neoprene surgical gloves, neoprene surgical gloves, Cardinal Health surgical gloves, sterile powder-free surgical gloves, non-latex surgical gloves, chemo-tested surgical gloves
Reviews
Rating Snapshot
No reviews yet — be the first to share your thoughts.
FAQs
Are Protexis Neoprene Surgical Gloves sterile?
Yes. Each right-and-left glove pair is provided in sterile surgical packaging.
Are these exam gloves?
No. Protexis Neoprene gloves are sterile, hand-specific surgical gloves. They are different from loose, ambidextrous, usually nonsterile examination gloves.
Are Protexis Neoprene gloves latex-free?
Cardinal Health states that they are made from synthetic neoprene and are not made with natural rubber latex. The FDA recommends this wording instead of the absolute term “latex-free.”
Are they powder-free?
Yes. The manufacturer identifies them as powder-free and reports a powder-residue limit below 2 mg per glove.
What material are they made from?
The primary glove material is synthetic neoprene, also known as polychloroprene. The product also has a nitrile coating.
Are these nitrile gloves?
No. They are neoprene surgical gloves with a nitrile coating. They should not be confused with standard nitrile examination gloves.
Are the gloves ambidextrous?
No. They are hand-specific, with separate right and left gloves.
How many gloves are in a box?
Each box contains 50 sterile pairs, equivalent to 100 individual gloves.
What sizes does Balego currently offer?
The current Balego page lists sizes 5.5, 6.5, and 8.0.
What is the length?
The target glove length is approximately 12 inches, or 305 mm.
What is the fingertip thickness?
The target fingertip thickness is approximately 6.7 mils, or 0.17 mm.
What is the AQL?
The manufacturer reports a 0.65 AQL for freedom from holes. Lower AQL values represent stricter inspection thresholds.
Are the gloves tested for chemotherapy use?
They have been tested for permeation by multiple chemotherapy agents in accordance with ASTM D6978. Suitability depends on the specific medication, concentration, and exposure period.
Can these gloves be used with carmustine?
No, Cardinal Health warns not to use Protexis Neoprene Surgical Gloves with carmustine at 3.3 mg/mL.
Are these gloves reusable?
No. They are sterile, single-use surgical gloves and should be discarded after use.
Are they hypoallergenic?
The gloves are not made with natural rubber latex, but they should not be described as hypoallergenic. Individuals may be sensitive to other glove ingredients or processing chemicals.




