Four selectable therapies, preset and custom programs, and rechargeable power in one handheld device.
The Richmar InTENSity Select Combo II combines TENS, NMES, interferential (IF/IFC), and Russian stimulation. Choose DI2195 when your approved treatment plan needs these modalities in a two-channel device with an LCD and push-button controls.
Check the model before reordering. Select Combo II DI2195 is not the original Select Combo DI8195. This rechargeable version includes Russian stimulation, not microcurrent.
Starter electrodes, leads, and charging accessories are included. Prescription required. We provide free standard U.S. shipping with no minimum purchase. Review the current price and availability beside the buying controls. Applicable tax is additional.
Included starting supplies
| Component | Included quantity |
|---|---|
| InTENSity Select Combo II DI2195 stimulator | 1 |
| Lead-wire assemblies | 2 |
| Reusable self-adhering electrodes | 4 pads, 2 x 2 inches |
| Rechargeable lithium-ion battery pack | 1 |
| USB charging cable and wall charger | 1 of each |
| Instruction manual and quick-start guide | 1 of each |
Quantity 1 purchases one device package, not an individual electrode or a replacement battery. The included pads and leads provide the starting electrode connections; additional pads are replenishment supplies. The required electrode arrangement still depends on the selected modality and clinical instructions.
Arrange your prescription.
Contact our team and identify InTENSity Select Combo II, model DI2195. Include your order number if you have already purchased. Ask which document-delivery method you or your prescriber's office should use; do not paste medical documents into the general contact form.
Our prescription-submission policy explains the process. Confirm receipt, any remaining requirements, and shipping status separately. Sending the prescription does not itself confirm that review is complete or an order has shipped.
Presets for navigation; U1 for approved custom settings
The interface combines four modalities, six body-area groups, and three program choices: P1, P2, and U1. That produces 72 program combinations, not 72 individually prescribed treatments. P1 and P2 are preset selections; U1 exposes the adjustable parameters available for the chosen modality.
The useful question is whether the selected mode can reproduce the required program. A parameter available in TENS is not automatically adjustable over the same range in NMES or Russian stimulation.
| Mode | Purchase-relevant custom-program capability |
|---|---|
| TENS | U1 offers a 1-150 Hz pulse rate, 50-400 microsecond pulse width, and 5-90-minute treatment time. |
| NMES | U1 offers 1-100 Hz, 200-400 microseconds, 5-30-second contraction, 5-60-second relaxation, and 1-9-second ramp settings. Operation is synchronous. |
| IF / IFC | Custom controls include beat-frequency limits and sweep-cycle settings. Do not interpret an advertised maximum carrier frequency as a freely selectable setting in every program. |
| Russian / RUSS | A separate stimulation selection with adjustable work/rest and ramp controls; its U1 treatment timer is 5-60 minutes, not the 90-minute maximum available in other modes. |
These are equipment capabilities, not treatment recommendations. Check the supplied instructions for the exact revision, selectable increments, and valid combinations. Our prescribed-settings compatibility guide explains the checks. Our Select Combo II manual and setup guide contain the operating sequence.
Select Combo II versus the original Select Combo.
| Buying consideration | Select Combo II - DI2195. | Original Select Combo - DI8195 |
|---|---|---|
| Modalities | TENS, NMES, IF, and Russian | TENS, EMS, IF, and microcurrent |
| Power | Rechargeable lithium-ion battery | Replaceable 9V battery or specified AC adapter |
| Program interface | Body-area selections with P1, P2, and U1 | Different controls and mode structure; use its own manual. |
| Main distinction | Rechargeable format with Russian stimulation | Microcurrent capability instead of Russian stimulation |
A newer name does not mean every feature of the original is retained. Match the actual modality and power requirement before substituting devices. For other formats, browse our NMES and EMS devices.
InTENSity Select Combo II purchasing FAQs
Can one channel run TENS while the other runs NMES?
No. The selected modality and program are shared; each channel's intensity can be adjusted separately. Two isolated outputs do not mean two independent therapy selections. For a different architecture, compare the Chattanooga Continuum, which offers 1+1 programming, and have your clinician approve the device choice.
Can it operate while plugged into the charger?
No. Stop treatment, switch the device off, and disconnect the patient leads and electrodes before charging. The USB cable and wall charger recharge the battery; they are not an AC-treatment option. Use the specified charging equipment rather than choosing a charger solely because its connector fits.
Does selecting a body-area icon tell me where to place the pads?
No. The icons organize program choices; they do not replace electrode-placement instructions or diagnosis. A neck icon does not authorize placement over the throat or front of the neck. Follow the prescribed placement and all restrictions in the supplied manual.
What does the treatment-use memory measure?
It stores operating records and accumulated use time, not muscle strength, correct placement, or treatment success. Record capacity should be checked against your unit's manual revision. Review use history alongside the actual response with your treating professional.
Which replacement electrodes and lead wires fit DI2195?
Richmar lists WW3005 lead wires and EP2020WC2-INTM 2-inch-square electrodes. Our 45-inch WW3005 lead-wire pack contains two lead assemblies. Match the device connector as well as the electrode connection.
Our InTENSity 2-inch-square electrode pack contains 40 pads in ten four-pad pouches. That is ten complete four-pad replacement sets, not ten guaranteed treatment sessions. Keep used electrodes assigned to one person and follow their replacement instructions.
What warranty comes with the device?
Richmar lists a one-year device warranty, subject to its terms. Normal wear of accessory supplies is not the same as a device defect. Contact us with your order information for service guidance; warranty coverage and return eligibility are separate matters.
Before the first treatment
Read the complete supplied instructions and use the device under appropriate professional supervision. Do not use with a pacemaker or implanted defibrillator, or apply stimulation through the head, over the front of the neck, or across the chest. Do not use while sleeping, driving, or bathing. Stop for burning, painful stimulation, or a skin reaction. This summary does not replace the full contraindications and warnings.
Ready to order? Confirm DI2195, the required modality and program, and the number of device packages. Keep our manual and troubleshooting guide available for setup and ongoing support.
© Balego Inc. All rights reserved.
Reviews
Rating Snapshot
No reviews yet — be the first to share your thoughts.
FAQs
What is the InTENSity Select Combo II used for?
The InTENSity Select Combo II is a portable electrotherapy device with TENS, NMES, interferential, and Russian stimulation modes. It is used for clinician-directed pain modulation and muscle stimulation programs.
Is the Select Combo II only a TENS unit?
No. It includes TENS, but it also includes NMES, Interferential, and Russian stimulation.
What is the difference between TENS and NMES?
TENS is generally used for sensory nerve stimulation and temporary pain modulation support. NMES is used to create muscle contractions for muscle activation and re-education when appropriate. For a full comparison, read Balego TENS vs. NMES.
What is interferential stimulation?
Interferential stimulation, often called IF or IFC, uses medium-frequency stimulation with a beat-frequency effect. It is often selected for broader pain-modulation style electrotherapy programs.
What is Russian stimulation?
Russian stimulation uses a medium-frequency carrier delivered in bursts. It is typically used for muscle contraction programs such as strengthening or re-education when clinically appropriate.
How many channels does it have?
The Select Combo II has two isolated channels, allowing one or two electrode-pair setups.
Is it rechargeable?
Yes. The device uses a rechargeable lithium battery pack and includes charging accessories.
Can it be used while charging?
No. Disconnect the device from the patient and do not use it while charging.
What electrodes work with the Select Combo II?
Use compatible self-adhesive electrotherapy electrodes with the correct lead-wire connection. Balego replacement options include Balego TENS/NMES/FES electrodes, DURA-STICK PLUS electrodes, and the full electrotherapy electrodes collection.
Please help! We can’t get it started; we follow the set for IF for the shoulder, and nothing is happening??
The most likely issue is that selecting IF + Shoulder + a program does not actually start the stimulation. On the Select Combo II, the output remains at 0 mA until the user presses CH1+ and/or CH2+. Each channel’s intensity must then be increased separately. Our operating guide confirms this sequence and notes that an incomplete electrode circuit can also cause a channel to remain at or reset to zero.
Here is a customer-ready response:
Absolutely—we can help. The InTENSity Select Combo II can be somewhat confusing the first time you use the IF setting because selecting IF and the Shoulder program does not automatically start the electrical output.
Please try the following:
- Ensure the unit is not connected to the charger. The Select Combo II cannot provide treatment while charging.
- Verify the electrode connections. Each active channel needs a complete pair of electrodes:
- Channel 1 lead wire → 2 electrodes
- Channel 2 lead wire → 2 electrodes, if you are using the second channel
- Push the electrode pins fully into the electrode connectors and ensure the lead-wire plug is seated firmly in the top of the unit.
- Apply the electrodes to clean, dry skin and ensure that the entire gel surface is making proper contact.
- Turn the unit on.
- Press the M/II button until IF appears on the display.
- Press the Shoulder button and select the prescribed P1, P2, or U1 program.
- This is the important step: press CH1+ to begin increasing the output on Channel 1. If you are using both channels, also press CH2+ to increase Channel 2.Start at zero and increase the intensity gradually. The IF program can be selected correctly on the screen while the actual stimulation intensity is still at 0, so nothing will be felt until the channel intensity is raised.
If you press CH1+ or CH2+ and the intensity will not increase or immediately drops back to zero, the unit is usually detecting an incomplete electrode circuit. Check:
- Both electrodes are connected to that channel.
- Electrode pins are pushed completely into the pads.
- The lead wire is fully inserted into the unit.
- The pads are firmly adhered to the skin.
- The pads are not dried out or lifting around the edges.
- The lead wire does not appear damaged.
If using only one channel, disconnect the unused lead wire rather than leaving it plugged into the unit without electrodes attached.
Also watch for a lock symbol. The controls automatically lock after approximately 20 seconds during treatment. If you see the lock symbol, press CH1− or CH2− once to unlock the controls, then make your adjustment.
You can find the complete Balego setup and troubleshooting instructions here:
InTENSity Select Combo II Manual: Setup, Programs & Troubleshooting
And the product page is here:
InTENSity Select Combo II DI2195
If the channel intensity numbers increase normally but you still feel absolutely no stimulation, try the other lead wire/channel to help determine whether the problem is with an electrode, lead wire, or the unit itself.
For shoulder treatment, follow the electrode-placement and treatment instructions provided by your healthcare professional. The “Shoulder” button selects the device program; it does not by itself specify where the electrodes should be placed.
One detail I would emphasize to the customer is Step 7. The guide specifically says that after choosing IF and the shoulder program, the user must press the appropriate CH+ button to begin output; it also confirms that poor pad/lead contact can cause the channel to reset to zero.
Need recommendation on NMES for MUSCLE STIM for a patient for home unit ideally ($100-150 price range). I'm his PT and would like to help him out with recs, thanks
Hello,
Thank you for reaching out. For a home muscle-stimulation program, we would suggest reviewing the InTENSity Twin Stim IV first. It comes in below your budget and provides adjustable NMES settings you can configure for your patient.
InTENSity Twin Stim IV — $79.95
- Two channels with independently adjustable intensity.
- NMES output up to 100 mA per channel at a 1,000-ohm load.
- Adjustable NMES frequency of 1–100 Hz and pulse width of 200–400 µs.
- Customizable contraction, relaxation, and ramp settings.
- Rechargeable battery and treatment-use tracking.
- Includes starter electrodes, lead wires, and charging accessories.
Our Twin Stim IV setup and programming guide provides additional operating information.
InTENSity Select Combo II—$129.95
- Fits within your requested $100–$150 range.
- Provides NMES and TENS, plus interferential and Russian stimulation.
- Offers adjustable NMES pulse width, frequency, contraction/rest timing, and ramp settings.
- Rechargeable, with starter electrodes, lead wires, and charging accessories included.
We would consider this option if those additional modalities are part of your intended treatment plan.
Both units require a prescription, and we provide free standard U.S. shipping. Applicable sales tax is additional. Our prescription-submission guide explains the ordering process.
Please let us know which muscle group you are targeting and any required pulse width, frequency, work/rest timing, or channel configuration. We can help confirm that the device accommodates your intended home program before your patient orders.
Best regards,
Is the Select Combo II better than the Twin Stim IV?
The Select Combo II is more versatile because it adds interferential and Russian stimulation. The Twin Stim IV is a good choice when the user only needs TENS and NMES.
When should I choose the Balego four-channel stim instead?
Choose the Balego Four Channel Stim when you need four independent channels for broader coverage, multiple treatment zones, or more electrode pairs at the same time.
Why did the output stop during treatment?
The device may detect poor pad contact, a loose lead wire, or an open circuit and reset output for safety. Check the pads, lead wires, skin contact, and battery before restarting at a low intensity.
Why does the unit lock after treatment starts?
The safety lock helps prevent accidental button presses during use. Follow the manual’s unlock instructions using the channel control buttons.
InTENSity Select Combo II, DI2195, Intensity Select Combo 2, TENS NMES IF Russian stim, TENS EMS IFC Russian unit, rechargeable electrotherapy device, portable TENS NMES unit, interferential therapy device, IFC stimulator, Russian stimulation device, dual channel stimulator, 4-mode electrotherapy unit, TENS NMES combo, muscle stimulator, pain relief TENS unit, physical therapy stim unit, rehab electrotherapy device